Integrated Circuits Inc. aP89341/170/085
Fig. 7 Edge, Unholdable, Non-retrigger
Fig. 8 Edge, Holdable
Fig. 9 SBT sequential trigger with Edge Holdable and Unholdable
TRIGGER MODES
There are three trigger modes available for aP89341/170/085 series which are determined by setting
M1 and M2 pins to logic HIGH or LOW.
⢠Key Trigger Mode (M1=0; M0=0);
⢠CPU Parallel Trigger Mode (M1=0; M0=1);
⢠CPU Serial Command Mode (M1=1; M0=0);
Ver 3.1
7