English
Language : 

SF0300BA01973S Datasheet, PDF (1/2 Pages) Integrated Circuit Systems – 300 MHz Filter
300 MHz Filter
Part Number
SF0300BA01973S
Micro Networks Corp., 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, www.micronetworks.com
TYPICAL PERFORMANCE
Horizontal: 2 MHz/div
SPECIFICATION
Vertical (from top):
10 dB/div
1 dB/div
200 ns/div
NOTE – All electrical specifications apply at room temperature (23 °C) only.
Notes:
1.
2.
3.
4.
5.
6.
PARAMETER
Center Frequency (FC) 1
Insertion Loss 2
3dB Bandwidth 3 4
40dB Bandwidth 3 4
Ultimate rejection at FC +/-(6 to 40) MHz 4
Average Passband Delay
Passband Amplitude Ripple 3 5
Passband Group Delay Ripple 3 6
Passband Phase Linearity 3 6
Return Loss at Input and Output 3 6
Triple Transit Suppression
Source and Load Impedance
Frequency change with Temperature (TC ≈ 20 °C)
Operating Temperature Range
Storage Temperature Range
Min
Typ
Max
299.935 300.010 300.085
15
19
3.2
3.3
4.6
4.7
45
50
1.67
1.8
0.75
1.0
70
200
3
10
10
40
46
50
-0.009(T-TC)2
-30
+70
-40
+85
Units
MHz
dB
MHz
MHz
dB
µs
dB p-p
ns p-p
deg p-p
dB
dB
Ω
kHz / °C2
°C
°C
Center frequency is defined as the mean of the upper and lower 3dB points. The typical room temperature center
frequency may be offset from 300 MHz to allow for frequency change with temperature.
Measured at the frequency at which the insertion loss is minimum.
All bandwidths are centered at FC.
Decibel level is relative to the insertion loss.
Over bandwidth FC +/- 1.2 MHz.
These parameters to be satisfied over the 3 dB bandwidth.
Rev 1.1 26-Apr-02
Page 1 of 2