English
Language : 

MC5XMS-7 Datasheet, PDF (1/1 Pages) Spectrum Microwave, Inc. – Double Balanced Mixer
Double Balanced Mixer
Communications Band
Model MC5xMS-7
Model MC5xMS-15
RF 3.5 to 15.0 GHz
Electrical Specifications : (1)
Parameter
SSB Conversion
loss:(2) (3)
Isolation
LO to RF:
LO to IF:
RF to IF:
IF to RF:
RF(GHz)
3.7-14.5
3.7-14.5
3.5-15.0
Conditions
LO(GHz)
3.7-14.5
3.7-14.5
3.5-15.0
IF(MHz)
DC-500
DC-2000
DC-4000
Specifications
Min
Typical Max
5.0 dB
7.0 dB
5.5 dB
7.5 dB
7.5 dB
9.5 dB
3.5-15.0
3.5-15.0
3.5-15.0
27 dB
23 dB
DC-2000
DC-4000
35 dB
38 dB
23 dB
20 dBm
14 dBm
LO Power
3 = +7 dBm
4 = +10 dBm
6 = +14 dBm
7 = +18 dBm
Input 1-dB
Compression Point:
Input Third Order
Intercept Point:
LO Power: (4)
3.5-15.0
3.5-15.0 DC-4000
3.5-15.0
3.5-15.0 DC-4000
3.5-15.0
3.5-15.0 DC-4000
+1 dBm
+4 dBm
+8 dBm
+12 dBm
+11 dBm
+14 dBm
+18 dBm
+22 dBm
+7 dBm
+10 dBm
+13 dBm
+18 dBm
MC53
MC54
MC56
MC57
MC53
MC54
MC56
MC57
MC53
MC54
MC56
MC57
Notes:
1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the
nominal LO power. Specifications indicated as typical are not guaranteed.
2. Noise figure is typically within ±0.5 dB of conversion loss if IF frequencies greater than 10 MHz.
3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C.
4. Usable LO drives are up to 2 dB below and 3 dB above nominal.
5. See Application note M112, for aid in selecting the outline and for mounting and installation information.
MC5xMS-7
Outline: MS3C
Typical
Performance
at 25˚C
MC5xMS-15
Outline: MS3D
ECTRU
All dimensions are in inches and [mm].
MICROWAVE
A Spectrum Control Business SPECTRUM MICROWAVE • 2144 Franklin Drive N.E. • Palm Bay, Florida 32905 • Phone: (888) 553-7531 • Fax: (888) 553-7532
www.specwave.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
600