English
Language : 

MC5XMS-5 Datasheet, PDF (1/1 Pages) Spectrum Microwave, Inc. – Double Balanced Mixer
Double Balanced Mixer
Communications Band
Electrical Specifications : (1)
Parameter
SSB Conversion
loss:(2) (3)
Isolation
LO to RF:
LO to IF:
RF to IF:
IF to RF:
RF(GHz)
5.0-10.0
5.0-10.0
3.5-12.0
3.5-12.0
Conditions
LO(GHz)
5.0-10.0
5.0-10.0
3.0-12.0
IF(MHz)
DC-500
DC-2000
DC-4000
5.0-10.0
3.5-12.0
DC-2000
DC-4000
Model MC5xMS-5
Model MC5xMS-14
RF 3.5 to 12.0 GHz
Specifications
Min Typical Max
4.8 dB
7.0 dB
5.8 dB
8.0 dB
7.0 dB
9.5 dB
30 dB
40 dB
32 dB
15 dB
20 dB
12 dB
LO Power
3 = +7 dBm
4 = +10 dBm
6 = +14 dBm
7 = +18 dBm
Input 1-dB
Compression Point:
Input Third Order
Intercept Point:
LO Power: (4)
3.5-12.0 3.5-12.0 DC-4000
3.5-12.0 3.5-12.0 DC-4000
3.5-12.0 3.5-12.0 DC-4000
+1 dBm
+4 dBm
+8 dBm
+12 dBm
+11 dBm
+14 dBm
+18 dBm
+22 dBm
+7 dBm
+10 dBm
+14 dBm
+18 dBm
MC53
MC54
MC56
MC57
MC53
MC54
MC56
MC57
MC53
MC54
MC56
MC57
Notes:
1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the nominal LO power. Specifications indicated as typical are not guaranteed.
2. Noise figure is typically within ±0.5 dB of conversion loss for IF frequencies greater than 10 MHz.
3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C.
4. Usable LO drives are up to 2 dB below and 3 dB above nominal.
5. See Application note M112, for aid in selecting the outline and for mounting and installation information.
MC5xMS-5
Outline: MS3C
Typical
Performance
at 25˚C
MC5xMS-14
Outline: MS3D
All dimensions are in inches and [mm].
ECTRU
MICROWAVE
A Spectrum Control Business SPECTRUM MICROWAVE • 2144 Franklin Drive N.E. • Palm Bay, Florida 32905 • Phone: (888) 553-7531 • Fax: (888) 553-7532
www.specwave.com SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58