Application Information
CT Capacitor
The capacitor that is connected from CT pin to GND determines the shutdown time and restart time.
Locked
Detection
Time
=
( ) C V ×
− 0.2V
CT
CTH
ICT1
( ) Restart
Time=
C×
CT
V V − CTH
CTL
ICT1
Shutdown
Time=
C (V V ) ×
CT
−
CTH
CTL
ICT2
For example:
VCC=12V, CCT=1µF
VCTL=1V, VCTH=3V, ICT1=2µA, ICT2=0.2µA
Locked Detection Time = 1.4s
Restart Time = 1s
Shutdown Time= 10s
The value of CCT must be considered with soft start up result.
RESET Capacitor
The capacitor that is connected from RESET pin to GND determines the Electric Motor Brakes. In the Power ON and
Quick Start before.
C I V Braking time =
×
RESET
RESET
RESET
EX:
IRESET = 1.2µA , VRESET = 1.9V , CRESET = 0.22µF
Braking time = 0.348s