APL5331_08 Datasheet, PDF (10/23 Pages) Anpec Electronics Coropration – 3A Bus Termination Regulator
APL5331
Operating Waveforms (Cont.)
3. Load Transient Response : I = +3A -> -3A -> +3A
OUT
- V = 2.5V, V = 3.3V
IN
CNTL
- VREF is 1.250V supplied by a regulator
- COUT = 470µF/10V, ESR = 30mΩ
-
I
OUT
slew
rate
=
±3A/µs
IOUT = +3A -> -3A
IOUT = +3A -> -3A -> +3A
VOUT
VOUT
IOUT
+3A
IOUT = -3A -> +3A
VOUT
IOUT
IOUT
Ch1 : VOUT, 50mV/Div, DC,
Offset = 1.250V
Ax1 : IOUT, 2A/Div
Time : 1µs/Div
-3A
Ch1 : VOUT, 50mV/Div, DC,
Offset = 1.250V
Ax1 : IOUT, 2A/Div
Time : 20µs/Div
Ch1 : VOUT, 50mV/Div, DC,
Offset = 1.250V
Ax1 : IOUT, 2A/Div
Time : 1µs/Div
4. Short-Circuit Test
- VIN = 2.5V, VCNTL = 3.3V
V is Shorted to GND
OUT
IOUT
VOUT is Shorted to VIN (2.5V)
IOUT
VOUT
Ch1 : VOUT, 500mV/Div, DC,
Ax1 : IOUT, 2A/Div
Time : 5ms/Div
VOUT
VOUT
IOUT
Ch1 : VOUT, 500mV/Div, DC,
Ax1 : IOUT, 2A/Div
Time : 5ms/Div