English
Language : 

X3C19P2-30S Datasheet, PDF (3/22 Pages) Anaren Microwave – 30 dB Directional Coupler
Insertion Loss and Power Derating Curves
0
-0.01
-0.02
Typical Insertion Loss Derating Curve for X3C19P2-30
typical insertion loss (f=1880Mhz)
typical insertion loss (f=1990Mhz)
typical insertion loss (f=2170Mhz)
typical insertion loss (f=2600Mhz)
-0.03
-0.04
-0.05
-0.06
-0.07
-100
-50
0
50
100
150
200
Temperature of the Part (oC)
400
350
300
250
200
150
100
50
0
0
Model X3C19P2-30S
Rev B
X3C19P2-30 Power Derating Curve
1400 - 2700Mhz
95
50
100
150
200
Mounting Interface Temperature (oC)
Insertion Loss Derating:
Power Derating:
The insertion loss, at a given frequency, of a group of
couplers is measured at 25C and then averaged. The
measurements are performed under small signal
conditions (i.e. using a Vector Network Analyzer). The
process is repeated at 85C and 150C. A best-fit line for
the measured data is computed and then plotted from -
55C to 150C.
The power handling and corresponding power derating
plots are a function of the thermal resistance, mounting
surface temperature (base plate temperature), maximum
continuous operating temperature of the coupler, and the
thermal insertion loss. The thermal insertion loss is
defined in the Power Handling section of the data sheet.
As the mounting interface temperature approaches the
maximum continuous operating temperature, the power
handling decreases to zero.
If mounting temperature is greater than 95C, Xinger
coupler will perform reliably as long as the input power is
derated to the curve above.
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392