English
Language : 

X3C17A1-03WS Datasheet, PDF (3/19 Pages) Anaren Microwave – Low Insertion Loss
`
Insertion Loss and Power Derating Curves
Typical Insertion Loss Derating Curve for X3C17A1-03 @2700Mhz
0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-100
-50
0
50
100
150
200
250
Temperature of the Part (oC)
Model X3C17A1-03WS
Rev B
PRELIMINARY
100
90
80
70
60
50
40
30
20
10
0
0
X3C17A1-03 Power Derating Curve
50
95 100
150
200
Mounting Interface Temperature (oC)
Insertion Loss Derating:
Power Derating:
The insertion loss, at a given frequency, of a group of
couplers is measured at 25C and then averaged. The
measurements are performed under small signal
conditions (i.e. using a Vector Network Analyzer). The
process is repeated at 85C and 150C. A best-fit line
for the measured data is computed and then plotted
from -55C to 150C.
The power handling and corresponding power derating
plots are a function of the thermal resistance, mounting
surface temperature (base plate temperature),
maximum continuous operating temperature of the
coupler, and the thermal insertion loss. The thermal
insertion loss is defined in the Power Handling section of
the data sheet.
As the mounting interface temperature approaches the
maximum continuous operating temperature, the power
handling decreases to zero.
If mounting temperature is greater than 95C, Xinger
coupler will perform reliably as long as the input power
is derated to the curve above.
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392