English
Language : 

X3C09P1-03S Datasheet, PDF (3/26 Pages) Anaren Microwave – Hybrid Coupler
`
Insertion Loss and Power Derating Curves
0
-0.02
-0.04
-0.06
Typical Insertion Loss Derating Curve for X3C09P1-03
typical insertion loss (f=894Mhz)
typical insertion loss (f=960Mhz)
typical insertion loss (f=1000Mhz)
typical insertion loss (f=800Mhz)
-0.08
-0.1
-0.12
-0.14
-0.16
-0.18
-100
-50
0
50
100
150
200
Temperature of the Part (oC)
Model X3C09P1-03S
Rev B
250
200
150
110
100
90
50
0
0
X3C09P1-03 Power Derating Curve
894Mhz & 960Mhz Band
800Mhz & 1000Mhz Band
50
100
150
200
Mounting Interface Temperature (oC)
Insertion Loss Derating:
Power Derating:
The insertion loss, at a given frequency, of a group of
couplers is measured at 25°C and then averaged. The
measurements are performed under small signal
conditions (i.e. using a Vector Network Analyzer). The
process is repeated at 85°C and 150°C. A best-fit line
for the measured data is computed and then plotted
from -55°C to 150°C.
The power handling and corresponding power derating
plots are a function of the thermal resistance, mounting
surface temperature (base plate temperature),
maximum continuous operating temperature of the
coupler, and the thermal insertion loss. The thermal
insertion loss is defined in the Power Handling section of
the data sheet.
As the mounting interface temperature approaches the
maximum continuous operating temperature, the power
handling decreases to zero.
If mounting temperature is greater than 95°C, Xinger
coupler will perform reliably as long as the input power
is derated to the curve above.
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392