English
Language : 

A1101R08C-EZ4X Datasheet, PDF (2/2 Pages) Anaren Microwave – The A1101R08C-EZ4x is a high-performance demonstration platform,
Pin Diagram
EZ4x Connections
PRELIMINARY
Nomenclature
Battery / USB:
ST1 P3.4 / UCA0TXD / UCA0SIMO
ST2 GND
ST3 RST / SBWTDIO
ST4 TEST / SBWTCK
ST5 VCC (3.6V)
ST6 P3.5 / UCA0RXD / UCA0SOMI
Interface:
P1
GND
P2
VCC
P3
P2.0 / ACLK / A0 / OA0I0
P4
P2.1 / TAINCLK / SMCLK / A1 /A0O
P5
P2.2 / TA0 / A2 / OA0I1
P6
P2.3 / TA1 / A3 / VREF– / VeREF–/ OA1I1 / OA1O
P7
P2.4 / TA2 / A4 / VREF+ / VeREF+/ OA1I0
P8
P4.3 / TB0 / A12 / OA0O
P9
P4.4 / TB1 / A13 / OA1O
P10 P4.5 / TB2 / A14 / OA0I3
P11 P4.6 / TBOUTH / A15 / OA1I3
P12 GND
P13 P2.6 / XIN (GDO0)
P14 P2.7 / XOUT (GDO2)
P15 P3.2 / UCB0SOMI / UCB0SCL
P16 P3.3 / UCB0CLK / UCA0STE
P17 P3.0 / UCB0STE / UCA0CLK / A5
P18 P3.1 / UCB0SIMO / UCB0SDA
This product shall not be used in any of the following products or systems
without prior express written permission from Anaren Microwave, Inc:
(i) implantable cardiac rhythm management systems, including without
limitation pacemakers, defibrillators and cardiac resynchronization devices;
(ii) external cardiac rhythm management systems that communicate
directly with one or more implantable medical devices; or
(iii) other devices used to monitor or treat cardiac function, including without
limitation pressure sensors, biochemical sensors and neurostimulators.
A
1 Chip series
2 Function
3 Frequency band
4 Form factor
5 Module Type
6 Firmware (EZ4 only)
(Anaren)
(1101, 2500)
(R = radio only)
(x100MHz)
(A = Internal Antenna, C = Connector)
(EM1 = Eval Module, EZ4 = EZ-430
Module)
(A = Access Point, E = End Point,
X = Custom (or no firmware)
To view the entire available family of AIR Modules &
Development options, please visit our website at:
http://www.anaren.com/content/File/AIR/AIRoverview.cfm
PLEASE NOTE: Additional information on the Texas Instruments
CC1101 Development Kit can be found in the company’s latest datasheet
release at http://www.ti.com
Caution! ESD sensitive device. Precautions
should be used when handling the device in
order to prevent permanent damage.
Anaren, Inc. / 6635 Kirkville Road / East Syracuse, NY 13057
800.411.6596 / http://www.anaren.com / air@anaren.com