A1101R08A Datasheet, PDF (1/2 Pages) Anaren Microwave – ETSI compliant, shielded package | |||
|
A1101R08A
PRELIMINARY
1101 Series
The A1101R08A is a high-performance, ETSI compliant radio module that
incorporates the Texas Instruments CC1101 transceiver chip in the indus-
tryâs smallest package (9 x 16 x 2.5mm).
Features
⢠Frequency range: 865-868 MHz
⢠ETSI compliant, shielded package
⢠Digital RSSI output
⢠Programmable output power up to +10dBm
⢠High sensitivity (-112 dBm at 1.2 kBaud, 868
MHz 1% packet error rate)
⢠Ultra-small package size 9 x 16 x 2.5mm
⢠LGA footprint
⢠RoHS compliant
⢠Operating temperature -40 to +85C
⢠Impedance-controlled, multi-layer PCB
⢠1.8 to 3.6 VDC
⢠Low current consumption (15 mA in RX, 1.2
kBaud, 868 MHz )
⢠200 nA sleep mode current consumption
⢠Efficient SPI interface; all registers can be
programmed with one âburstâ transfer
⢠Available in tape & reel and matrix tray
Benefits
⢠No RF engineering experience necessary
⢠No additional âIntentional Radiatorâ certifica-
tion required (ETSI EN 300 220)
⢠Minimal real estate required
⢠Easily implemented on a two layer PCB
⢠No additional harmonic filtering required
⢠100% RF-tested in production
⢠Common footprint for product family
⢠No additional DC decoupling required
⢠Integrated analog temperature sensor
⢠Excellent receiver selectivity and blocking
performance
⢠Suitable for frequency hopping systems,
thanks to a fast-settling frequency synthesizer
with 90 µs settling time
⢠Impedance-matched balun for optimized effi-
ciency
⢠Support for asynchronous and synchronous
serial receive/transmit mode for backwards
compatibility with existing radio communica-
tion protocols
Block diagram
PLEASE NOTE: Additional information on the Texas Instruments CC1101
device can be found in the companyâs latest datasheet release at
http://www.ti.com
This product shall not be used in any of the following products or systems
without prior express written permission from Anaren Microwave, Inc:
(i) implantable cardiac rhythm management systems, including without
limitation pacemakers, defibrillators and cardiac resynchronization devices;
(ii) external cardiac rhythm management systems that communicate
directly with one or more implantable medical devices; or
(iii) other devices used to monitor or treat cardiac function, including without
limitation pressure sensors, biochemical sensors and neurostimulators.