English
Language : 

AAT3680 Datasheet, PDF (4/18 Pages) Advanced Analogic Technologies – Lithium-Ion Linear Battery Charge Controller
AAT3680
Lithium-Ion Linear Battery Charge Controller
Electrical Characteristics (VIN = 4.5V to 15V, TA = -20 to 70°C unless otherwise noted. Typical
values are at TA=25°C)
Symbol Description
Conditions
Min Typ Max Units
IP
ISLEEP
ISTAT(HI)
VSTAT(LOW)
ISINK
VOL@DRV
VCH
VCS
VMIN
VTRICKLE
T2X
VTS1
VTS2
VTERM
VRCH
VUVLO
VOVP
VOCP
Operating Current
Sleep Mode Current
STAT high level output
leakage current
VIN = 5.5V
VIN = 5.5V, VCH = 4.1V, VCH = 4.2V
VCH = 8.2V, VCH = 8.4V
VIN = 5.5V
-1
STAT low level sink current
DRV pin sink current
DRV pin output low
VIN = 5.5V, ISINK = 5mA
VIN = 5.5V
ISINK = 5mA, VIN = 5.5V
AAT3680-4.1
TA = 25°C
see note 1
20
4.075
4.059
Output Charge Voltage
AAT3680-4.2
TA = 25°C
see note 1
AAT3680-8.2
TA = 25°C
see note 1
4.175
4.158
8.151
8.118
AAT3680-8.4
TA = 25°C
see note 1
8.350
8.316
Charge Current Regulation
VIN = 5.5V, VCH = 4.1V, VCH = 4.2V
VIN = 12V, VCH = 8.2V, VCH = 8.4V
AAT3680-4.1
90
90
2.94
Preconditioning Voltage Threshold
AAT3680-4.2
AAT3680-8.2
3.04
5.98
AAT3680-8.4
6.08
Trickle-Charge Current Regulation
T2X
floating
VCH
VCH
=
=
4.1V,
8.2V,
VCH
VCH
=
=
4.2V
8.4V
Trickle Charge Current Gain
T2X = VSS
Low Temperature Threshold
VIN = 15V
High Temperature Threshold
VIN = 15V
Charge termination threshold voltage
29.1
58.2
4
Battery Recharge Voltage Threshold
Undervoltage Lockout
Over-voltage Protection Threshold
VCH = 4.1V
VCH = 4.2V
VCH = 8.2V
VCH = 8.4V
VIN rising, TA = 25°C
3.92
4.018
7.84
8.306
3.5
Over-current Protection Threshold
0.5
2
3
0.3
0.4
4.100
4.100
4.200
4.200
8.200
8.200
8.400
8.400
100
100
3.0
3.1
6.1
6.2
10
10
1.8
30
60
12
4.00
4.10
8.00
8.20
4.0
4.4
200
3 mA
6
10
µA
+1 µA
0.6
V
mA
1.0
V
4.125
4.141
4.225
4.242
8.249
V
8.282
8.450
8.484
110
110
mV
3.06
3.16
6.22
V
6.32
mV
30.9
61.8
24
4.08
4.182
8.16
8.364
4.5
% VP
% VP
mV
V
V
V
% VCS
Note 1: The AAT3680 output charge voltage is specified over 0° to 50°C ambient temperature; operation over -20 to 70°C is guaranteed
by design.
4
3680.2003.4.0.91