English
Language : 

AAT3134 Datasheet, PDF (4/13 Pages) List of Unclassifed Manufacturers – High Efficiency 1X/1.5X Fractional Charge Pump for White LED Applications
AAT3134
High Efficiency 1X/1.5X Fractional
Charge Pump for White LED Applications
Electrical Characteristics1
VIN = 3.5V, CIN = COUT = C1 = C2 = 1.0µF; TA = -40°C to +85°C.
Unless otherwise noted, typical values are TA = 25°C.
Symbol Description
Input Power Supply
VIN
Operation Range
ICC
Operating Current
ISHDN
IDX(MAX)
I(D-Match)
Shutdown Current
Maximum Output Current
Current Matching Between
Any Two Outputs
Charge Pump Section
TSS
FCLK
Soft-Start Time
Clock Frequency
ηCP
Charge Pump Section Efficiency
EN/SET
VEN(L)
VEN(H)
TEN/SET LO
TEN/SET HI
TOFF
Input Current
Enable Threshold Low
Enable Threshold High
EN/SET Low Time
Minimum EN/SET High Time
EN/SET Off Timeout
EN/SET Input Leakage
Conditions
Min Typ Max Units
3.0 ≤ VIN ≤ 5.5, Active,
No Load Current
EN/SET = 0
VIN = 3.6, Code = 32
VD1:D4 = 3.6, VIN = 3.5V
VD5:VD6 = 3.6, VIN = 3.5V
2.7
5.5
V
1.8 3.5 mA
1.0 µA
18 20 22 mA
0.5
%
0.5
200
µs
1000
kHz
VIN = 3.5V, IOUT(TOTAL) = 120mA,
Measured from IN to OUT
93
%
VEN/SET < 0.5
VEN/SET > 1.4
VEN/SET < 0.5
0.5
V
1.4
V
0.3
75 µs
50
ns
500 µs
-1.0
1.0 µA
1. The AAT3134 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured
by design, characterization, and correlation with statistical process controls.
4
3134.2005.12.1.1