English
Language : 

AAT1141_0810 Datasheet, PDF (4/20 Pages) Advanced Analogic Technologies – Fast Transient 600mA Step-Down Converter
SwitchRegTM
PRODUCT DATASHEET
AAT1141
Fast Transient 600mA Step-Down Converter
Electrical Characteristics1
TA = -40°C to +85°C, unless otherwise noted. Typical values are TA = 25°C, VIN = 3.6V.
Symbol Description
Step-Down Converter
VIN
Input Voltage
VUVLO
UVLO Threshold
VOUT
VOUT
IQ
ISHDN
ILIM
RDS(ON)H
RDS(ON)L
ILXLEAK
ΔVLinereg
VOUT
IOUT
ROUT
TS
FOSC
TSD
THYS
EN
VEN(L)
VEN(H)
IEN
Output Voltage Tolerance
Output Voltage Range
Quiescent Current
Shutdown Current
P-Channel Current Limit
High Side Switch On Resistance
Low Side Switch On Resistance
LX Leakage Current
Line Regulation
Out Threshold Voltage Accuracy
Out Leakage Current
Out Impedance
Start-Up Time
Oscillator Frequency
Over-Temperature Shutdown Threshold
Over-Temperature Shutdown Hysteresis
Enable Threshold Low
Enable Threshold High
Input Low Current
Conditions
VIN Rising
Hysteresis
VIN Falling
IOUT = 0 to 600mA, VIN = 2.7V to 5.5V
No Load, 0.6V Adjustable Version
EN = AGND = PGND
VIN = 5.5V, VLX = 0 to VIN, EN = GND
VIN = 2.7V to 5.5V
0.6V Output, No Load, TA = 25°C
0.6V Output
>0.6V Output
From Enable to Output Regulation
TA = 25°C
VIN = VOUT = 5.5V
Min Typ Max Units
2.7
1.8
-3.5
0.6
800
588
250
1.2
5.5
2.7
100
+3.5
VIN
35 70
1.0
0.35
0.30
1
0.1
600 612
0.2
150
2.0 2.6
140
15
V
V
mV
V
%
V
μA
μA
mA
Ω
Ω
μA
%/V
mV
μA
kΩ
μs
MHz
°C
°C
1.4
-1.0
0.6
V
V
1.0
μA
1. The AAT1141 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured by design, characterization, and correla-
tion with statistical process controls.
4
www.analogictech.com
1141.2008.10.1.6