AWT6331
APPLICATION INFORMATION
To ensure proper performance, refer to all related
Application Notes on the ANADIGICS web site:
http://www.anadigics.com
Shutdown Mode
The power amplifier may be placed in a shutdown
mode by applying a logic low levels (see Operating
Ranges table) to both the VEN and VMODE voltages.
Power Modes
The power amplifier may be placed in either a Low
Power mode or a High Power mode by applying the
appropriate logic level (see Operating Ranges table)
to the VMODE voltage. The Power Control table lists
the recommended modes of operation for various
applications.
APPLICATION
Table 5: Power Control
POUT
POWER
LEVELS MODE
VEN
VMODE
CDMA - Switch Bypass
-*
Low +2.4 V 0 V
Shutdown
-*
Low
0 V +2.4 V
CDMA - PA
All
High +2.4 V +2.4 V
Shutdown
-
Shutdown 0 V
0V
*Dependent upon typical output power from Transceiver and phone design.
VENABLE
RFIN_PA
RFIN_SWITCH
VMODE
VBATT
C1
2.2 µF
1 VENABLE
2 VMODE
GND 10
GND 9
3 RFIN_PA
RFOUT 8
4 RFIN_SWITCH
VCC 7
5 VBATT
C2
0.01 F
GND
VCC 6
at slug
GND
at slug
C6
68 pF
RFOUT
C3
330 pF
C4
0.01 µF
VCC
C5
2.2 µF
Figure 3: Application Circuit
Data Sheet - Rev 2.1
5