ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
MIN MAX
UNIT
Supply Voltage (VCC)
0
+8
V
AGC Voltage (VAGC)
0
+5
V
RF Input Power (PIN)
-
+25 dBmV/ch
Storage Temperature
-65 +150
°C
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure
to absolute ratings for extended periods of time may adversely affect
reliability.
ACA2604
PARAMETER
Table 3: Operating Ranges
MIN TYP MAX
UNIT
COMMENTS
Operating Frequency (f)
50
-
870
MHz
Supply Voltage (VCC)
-
+5
-
V
RF Output Power (POUT)
-
+18
-
dBmV/ch
Case Temperature (TC)
-40
-
+110
°C
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
Data Sheet - Rev 2.1
3
11/2008