ELECTRICAL CHARACTERISTICS
Table 2: Absolute Mimimum and Maximum Ratings
PARAMETER
MIN MAX UNIT
Supply (pins 12, 13)
0
+28
VDC
Current Adjust (pin 6)
0
+4
VDC
RF Power at Inputs (pins 4, 5)
-
+75 dBmV
Storage Temperature
-65 +150
°C
Soldering Temperature
-
+260
°C
Soldering Time
-
5.0
Sec
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
Notes:
1. Pins 2, 4, 5 and 7 should be AC-coupled. No external DC bias should
be applied.
2. Pins 11 and 14 are bias feeds for input amplifiers 1A and 1B. No
external DC bias should be applied.
3. Pins 10 and 15 receive DC bias directly from pins 11 and 14. No other
external bias should be applied.
ACA2404
PARAMETER
Table 3: Operating Ranges
MIN TYP
MAX
UNIT
Supply: VDD (pins 12, 13)
Current Adjust (pin 6)
-
+24
-
-
+3
-
VDC
VDC
RF Frequency
40
-
870
MHz
Case Temperature
-40
-
+110
°C
The device may be operated safely over these conditions; however, parametric
performance is guaranteed only over the conditions defined in the electrical
specifications.