English
Language : 

ACA2601 Datasheet, PDF (11/20 Pages) ANADIGICS, Inc – Fiber-to-the-Home RF Amplifier
All performance data measured using application circuit with input photodiode, as shown in Figure 16.
ACA2601
Figure 10: Gain Flatness To Best Fit Line vs. Frequency over Temperature
(VCC = + 5 V, VAGC = 0 V)
2
1.5
1
+115C
0.5
+100C
+60C
+40C
0
+15C
-5C
-25C
-0.5
-35C
-1
-1.5
-2
0
100
200
300
400
500
600
700
800
900
1000
Frequency (MHz)
Table 7: Gain Flatness to Best Fit Line
(VAGC = 0 V)
Temp (oC)
Tilt (dB)
Flatness (dB)
115
5.4
1.2
100
5.7
1.2
60
6.1
1.1
40
6.3
1.1
15
6.6
1.1
-5
6.8
1.2
-25
6.9
1.3
-35
7
1.5
The best fit line is calculated
using the least mean squares
method:
y = m⋅x+b
m
=
∑
(x ⋅ y)−
∑x2 −
∑x⋅∑
n
(∑ x)2
n
y
b= ∑y −m⋅∑x
n
n
n = number of points
PRELIMINARY DATA SHEET - Rev 1.4
11
01/2006