AS1310 Datasheet, PDF (5/15 Pages) ams AG – Ultra Low Quiescent Current, Hysteretic DC-DC Step-Up Converter
AS1310
Datasheet - Electrical Characteristics
Table 3. Electrical Characteristics
Symbol
Parameter
Thermal Protection
Thermal Shutdown
Conditions
10°C Hysteresis
Min Typ Max Units
150
°C
1. The regulator is in startup mode until this voltage is reached. Caution: Do not apply full load current until the device output > 1.75V
2. LBO goes low in startup mode as well as during normal operation if:
1) The voltage at the LBI pin is below LBI threshold.
2) The voltage at the LBI pin is below 0.1V and VOUT is below 92.5% of its nominal value.
Note: All limits are guaranteed. The parameters with min and max values are guaranteed with production tests or SQC (Statistical Quality
Control) methods.
www.austriamicrosystems.com/DC-DC_Step-Up/AS1310
Revision 1.04
5 - 15