English
Language : 

AS3543_11 Datasheet, PDF (47/92 Pages) ams AG – High End Stereo Audio Codec wi th System PMU
AS3543 3v2
Data Sheet - Detailed Description - SYSTEM Functions
10.3 Supervisor
10.3.1 General
This supervisor function can be used for automatic detection of BVDD brown out or junction over-temperature condi-
tion.
10.3.2 BVDD Supervision
The BVDD supervision interrupt level is set to 175mV above regulator output AVDD27. When BVDD reaches this level
an interrupt can be generated.
lid If AVDD27 reaches the “programmed level of AVDD27” -10% for more than 680us, the AFE shuts down automatically,
if the shutdown is not disabled.
10.3.3 Junction Temperature Supervision
a The temperature supervision level can also be set by 5 bits (120 to –15ºC). If the temperature reaches this level, an
interrupt can be generated. The over-temperature shutdown level is always 20ºC higher.
v 10.3.4 Power Rail Monitoring
ill The 4 main regulators as well as the DCDC15 booster and the system supply AVDD27 have an extra monitor which
observes the output voltage of the regulators. This power rail monitors are independent from the 10bit ADC. To activate
these please see related registers. For a shut down the voltage of the regulator has to be 10% or more below the pro-
t grammed value for more than 680us.
G s 10.3.5 Register Description
Table 34. Supervisor Related Register
A t Name
Base
s n SUPERVISOR
2-wire serial
e IRQENRD_0
m t IRQENRD_1
a n IRQENRD_2
IRQENRD_3
o IRQENRD_4
2-wire serial
2-wire serial
2-wire serial
2-wire serial
2-wire serial
Offset
21h
23h
24h
25h
26h
27h
Description
Low battery shutdown disable and junction temperature
supervision threshold levels
Enable/disable PVDD/CVDD monitoring interrupt and shutdown
Enable/disable PVDD/CVDD monitoring interrupt and shutdown
Enable/disable battery brown out interrupt
Enable/disable junction temperature interrupt
Enable/disable AVDD27 and DCDC15 monitoring interrupt
c 10.4 Interrupt Generation
l 10.4.1 General
a All interrupt sources can get enabled or disabled by corresponding bits in the 5 IRQ-bytes. By default no interrupt
source is enabled.
ic The XIRQ output can be configured to operate in push/pull (2 different driver strengths), open-drain mode or to be tri-
state. The signal polarity can be defined as active-low or active-high. Default state is open-drain active-low. For a more
n detailed description of the GPIO functionality of this pin please refer to chapter GPIO Pins on page 50.
10.4.2 IRQ Source Interpretation
h There are 3 different modules to process interrupt sources:
c LEVEL
e The IRQ output is kept active as long as the interrupt source is present and this IRQ-Bit is enabled
TEDGE
The IRQ gets active with a high going edge of this source. The IRQ stays active until the corresponding IRQ-Register
gets read.
www.austriamicrosystems.com
Revision 1.11
46 - 91