English
Language : 

TMD3782 Datasheet, PDF (16/34 Pages) ams AG – Color Light-To-Digital Converter with Proximity Sensing
Address Register Name R/W
Register Function
0x19
0x1A
0x1B
0x1C
0x1D
GDATAH
BDATA
BDATAH
PDATA
PDATAH
R
Green ADC high data register
R
Blue ADC low data register
R
Blue ADC high data register
R
Proximity ADC low data register
R
Proximity ADC high data register
Reset
Value
0x00
0x00
0x00
0x00
0x00
The mechanics of accessing a specific register depends on the
specific protocol used. In general, the COMMAND register is
written first to specify the specific control/status register for
following read/write operations.
TMD3782 – 16
Datasheet - Mar. 2013 - V2