AS5043
Data Sheet – Programming the AS5043
Figure 13: Zero Position Programming (shown for 360° mode)
VDD5V
5V
analog
output
voltage
the output can be electrically rotated to
match a given output voltage to any
mechanical position
2V
lid 0V
0°
90°
180°
270°
Mechanical
360° angle
a 12.2 Analog Mode Programming
v The analog output can be configured in many ways:
ill It consists of three major building blocks,
a digital range preselector,
a 10-bit Digital-to-Analog-Converter (DAC)
t and an OP-AMP buffer stage.
G s In the default configuration (all OTP bits = 0), the analog output is set for 360° operation, internal DAC reference
(VDD5V/2), external OPAMP gain, 0-100% ratiometric to VDD5V.
A t Shown below is a typical example for a 0°-360° range, 0-5V output. The complete application requires only one external
component, a buffer capacitor at VDD3V3 and has only 3 connections VDD, VSS and Vout (connectors 1-3).
s n Note: the default setting for the OPAMP feedback path is:FB_intEn=0=external. The external resistors Rf and Rg must be
e installed. In the programmed state (FB_intEn=1=internal), these resistors do not need to be installed as the feedback
Technicaaml cont path is internal (Rf_int and Rg_int).