English
Language : 

TSL2571 Datasheet, PDF (13/25 Pages) TEXAS ADVANCED OPTOELECTRONIC SOLUTIONS – LIGHT-TO-DIGITAL CONVERTER
TSL2571
LIGHT-TO-DIGITAL CONVERTER
TAOS117A − FEBRUARY 2011
Register Set
The device is controlled and monitored by data registers and a command register accessed through the serial
interface. These registers provide for a variety of control functions and can be read to determine results of the
ADC conversions. The register set is summarized in Table 1.
Table 1. Register Address
ADDRESS
−−
0x00
lid 0x01
0x03
0x04
a 0x05
v 0x06
0x07
ill 0x0C
0x0D
0x0F
t 0x12
G s 0x13
0x14
A t 0x15
0x16
s n 0x17
RESISTER NAME
COMMAND
ENABLE
ATIME
WTIME
AILTL
AILTH
AIHTL
AIHTH
PERS
CONFIG
CONTROL
ID
STATUS
C0DATA
C0DATAH
C1DATA
C1DATAH
R/W
REGISTER FUNCTION
W Specifies register address
R/W Enables states and interrupts
R/W ALS ADC time
R/W Wait time
R/W ALS interrupt low threshold low byte
R/W ALS interrupt low threshold high byte
R/W ALS interrupt high threshold low byte
R/W ALS interrupt high threshold high byte
R/W Interrupt persistence filters
R/W Configuration
R/W Control register
R Device ID
R Device status
R CH0 ADC low data register
R CH0 ADC high data register
R CH1 ADC low data register
R CH1 ADC high data register
RESET VALUE
0x00
0x00
0xFF
0xFF
0x00
0x00
0x00
0x00
0x00
0x00
0x00
ID
0x00
0x00
0x00
0x00
0x00
m te The mechanics of accessing a specific register depends on the specific protocol used. See the section on I2C
a n protocols on the previous pages. In general, the COMMAND register is written first to specify the specific
Technical co control/status register for following read/write operations.
Copyright E 2011, TAOS Inc.
12
r
www.taosinc.com
The LUMENOLOGY r Company
r