English
Language : 

7-8905 Datasheet, PDF (7/45 Pages) Amphenol Corporation – Amphenol 97 Series Standard Cylindrical Connector
97 series solder type
insert availability, cont.
Insert
Total
Mechanical
Spacing
Service
Contact Size
Number Contacts
Rating
Inches mm
0 4 8 12
16
22-26*
7 1/8 3.18
2
5
22-27
1/8 3.18
D
9
1/16 1.57
A
1
8
22-28†
7 1/16 1.57
A
7
22-34
5 1/8 3.18
D
3
2
24-2
7 1/8 3.18
D
7
24-5†
16 1/16 1.57
A
16
1/8 3.18
D
3
24-6
8
1/16 1.57
A
5
24-7
16 1/16 1.57
A
2
14
24-9†
2 1/16 1.57
A
2
24-10
7 1/16 1.57
A
7
24-11
9 1/16 1.57
A
36
24-12
5 1/16 1.57
A
2
3
24-16
1/8 3.18
D
7
1/16 1.57
A
1
3
3
24-19†
12 1/16 1.57
12
24-20✦
11 1/8 3.18
D
2
9
24-21
10 1/8 3.18
D
1
9
24-22✦
4 1/8 3.18
D
4
24-27
7 3/16 4.75
E
7
24-28
24 1/16 1.57 INST.
24
28-1
1/8 3.18
D
9
1/16 1.57
A
12
24
28-2
14 1/8 3.18
D
2
12
28-3
3 3/16 4.75
E
3
28-6†
3 1/8 3.18
D
3
1/16 1.57
A
9
28-8
12 1/8 3.18
D
1
3/16 4.75
E
2
28-9
12 1/8 3.18
D
6
6
28-10
1/8 3.18
D
7
1/16 1.57
A
1
22 2
28-11
22 1/16 1.57
A
4
18
28-12
26 1/16 1.57
A
26
28-15†
35 1/16 1.57
A
35
28-16†
20 1/16 1.57
A
20
1/4 6.35
B
1
28-17
15 1/8 3.18
D
3
1/16 1.57
A
11
5/16 7.92
C
1
1/8 3.18
D
5
28-18
12
1/16 1.57
A
2
INST.
4
1/4 6.35
B
2
28-19
10 1/8 3.18
D
2
1/16 1.57
A
4
2
Insert
Total
Mechanical
Spacing
Service
Contact Size
Number Contacts
Rating
Inches mm
0 4 8 12
16
28-20
14 1/16 1.57
A
10
4
28-21
37 1/16 1.57
A
37
32-5†
2 1/8 3.18
D
2
32-6
23 1/16 1.57
A
23
2
16
32-7
1/16 1.57
A
35
INST.
7
24
4
32-8†
30 1/16 1.57
A
6
24
32-13
23 1/8 3.18
D
5
18
32-17
4 1/8 3.18
D
4
32-414
52 1/16 1.57
A
52
36-1†
22 1/8 3.18
D
4
18
36-5
4 1/16 1.57
A
4
36-6
6 1/16 1.57
A
24
36-7
47 1/16 1.57
A
7
40
36-8
47 1/16 1.57
A
1
46
36-9
31 1/16 1.57
A
1 2 14 14
36-10
48 1/16 1.57
A
48
1/16 1.57
A
34
36-15
35
1/8 3.18
D
1
36-403*
52 1/16 1.57
A
52
Not all insert arrangements are currently available for environmental individual
wire seal. Consult Amphenol, Sidney, NY for availability.
† Inactive for new military design, but available for replacement or for non-mili-
tary purposes.
* “MS” number not assigned. Use “97” prefix in place of “MS” in completing cata-
log number. See how to order, page 19.
✦ Molded-in pin (MIP) insert requires (910) deviation. See how to order, pg. 19.
5