English
Language : 

ZZL-4016-10P Datasheet, PDF (5/39 Pages) Amphenol Corporation – Amphenol pyle MIL-C-26500 Connectors
MIL-C-26500
specifications
TEST REQUIREMENTS
MILITARY SPECIFICATIONS
PYLE CONNECTOR CAPABILITIES
Air Leakage (Classes E, G, R & K)
Altitude Immersion
(Classes E, G, R & K)
Contact Retention
(Classes E, G, R & K)
Collet Retention
Contact Insertion Force
(Classes E, G, R & K)
Coupling Forces
Fluid Resistance
(Classes E, G, R & K)
Ground Resistance (Class G)
High Potential
(Classes E, G, R & K)
Insert Retention (Classes E, G, R & K)
Insulation Resistance
(Classes E, G, R & K)
Low Temperature
(Classes E, G, R & K)
Magnetic Permeability
(Classes E, G, R & K)
Moisture Resistance
(Classes E, G, R & K)
Ozone Exposure (Classes E, G, R & K)
Physical Shock
(Classes E, G, R & K)
Sand & Dust Exposure
(Classes E, G, R & K)
Temperature Life
(Classes E, G, R & K)
Thermal Shock (Mated)
(Classes E, G, R & K)
Vibration
(Classes E, G, R & K)
Flame Resistance (Class K)
1 cu. inch per hr. max. -55°C (-67°F)
Sea level 1 inch of mercury, 3 cycles
(IR 5000 megohms hi-pot 1500 volts-submerged)
Size 20 contact 20 lbs. min.
Size 16 contact 25 lbs. min.
Size 12 contact 30 lbs.min.
No requirement
All size contacts 10 lbs. max.
Torque required to couple and uncouple mating plugs
and receptacles is not to exceed the values listed:
Shell size
8 10 12 14 16 18 20 22 24
Torque inch lbs. 9 10 14 17 23 26 31 38 46
20 hrs. immersion in MIL-H-5606 hydraulic fluid and MIL-L-9236
lubrication oil. Must meet hi-pot.
.250 ohms backshell of plug to rear of receptacle flange.
1500 VRMS mated & unmated at sea level
1000 VRMS mated to 110,000 ft. altitude
75 psi. from either direction for 5 seconds.
21°C (70°F), 5000 megohms between adjacent contacts and any
contact and shell.
-55°C (-67°F)
2 mu. maximum
1000 megohms min. per mil-std. 202 method 106
0.10 to .015% ozone exposure
50 G’s, 3 axis, per mil-std-202, method 213, test condition C,
wired to monitor 1 microsecond discontinuity.
No requirement.
Connector fully functional for 1000 hours at 200°C (392°F) ambi-
ent internal temperature 238°C (460°F)
Cycled five times from -55°C to 260°C, held for 30 minutes at
each temperature and transferred to the other in 2 minutes or
less, with no evidence of damage.
MIL-Std. 202 method 204 condition “D” at R. T.,
-55°C (-67°F) and +200°C (+392°F).
Performance requirements of Paragraph 4.5.18
Fireproof (Class K of MIL-C-5015D)
Comply
Comply
Exceeds specifications
Without damage to the collet or its retention
means: Size 20 – 75 lbs. min.
Size 16 – 140 lbs. min
Size 12 – 160 lbs. min.
Comply
Comply
20 hrs. min., fully functional physically and
electrically after immersion. No deteriora-
tion of resilient material.
Comply
Exceed with ample margin of safety.
Exceeds specifications.
Exceeds specifications.
Comply
Comply
Comply
Comply
Comply
Meet MIL-E-5272 condition “B”
Comply
Comply
Comply - monitored for a max. of 1 micro-
second discontinuity.
Exceeds specifications
3