C 091 D
Characteristics
General Characteristics
Standard Characteristics
Number of contacts
3
4
5 5 Stereo 6
7
7
8
12
14
View on termination side
of contact insert
2
1
3
23
1
4
3
2
4
15
425
1
3
3
2
4
6
15
4
5
3
6
7
1
2
425
1
3
67
425
183
67
Contact arrangement acc. to DIN
Contact arrangement acc. to IEC
Electrical Characteristics
Rated voltage
41 524 –
– 41 524 45 322 – 45 329 45 326 –
–
60130-9 60130-9 – 60130-9 60130-9 – 60130-9 60130-9 –
–
IEC 60664-1
300 V –~
100V –~
300 V –~
100 V –~
150 V –~
Rated voltage
UL 1977
250 V
60 V
Rated impulse withstand voltage IEC 60664-1
1500 V
1200 V
1500 V
1200 V
Pollution degree
IEC 60664-1
1
Installation category
IEC 60664-1
I
Insulation group
IEC 60664-1
II, 400 ≤ CTI < 600
Current rating
Insulation resistance
Contact resistance
Climatic Characteristics
Climatic category
IEC 60512-5-2
Test 5 b
UL 1977
IEC 60512-3-1
Test 3 a
IEC 60512-2-1
Test 2 a
IEC 60668-1
5 A / + 40 °C / + 104 °F
please refer also to current derating curves page 45
> 10 10 Ω
<5mΩ
40 / 100 / 56
3 A / + 40 °C /
+ 104 °F
Temperature range
Mechanical Characteristics
IP-degree
Insertion and withdrawal forces
Mechanical operation
Materials
Housing material
IEC 60668-1
IEC 60529
IEC60512-13-2 25 N
Test 13 b
90.oz
IEC 60512
Test 9 a
30 N
110.oz
- 40 °C ... + 100 °C / - 40 °F ... + 212 °F
35 N
125.oz
IP 67 / IP 65
50 N
180.oz
55 N
200.oz
Silver ≥ 500 mating cycles
Gold ≥ 1000 mating cycles
die cast, nickel plated
60 N
220.oz
50 N
180.oz
Dielectric material
thermoplastic
Sealing material
neoprene
Contact plating
silver plated / gold plated *
Further Characteristics
Termination technique
Wire gauge
Flammability
solder, crimp
solder: ≤ 0,5 mm2 / 20 AWG
crimp: 2 - 6 pol (excluding 5S): 0,09 - 1,00 mm2 / 28 - 18 AWG
crimp: 5S, 7, 7S and 8-pol.: 0,09 - 0,75 mm2 / 28 - 20 AWG
UL 94 V0
solder
≤ 0,25 mm2/24 AWG
Locking system
IEC 60130-9
metal screw coupling; tightening torque 0,5 - 0,7 Nm
UL
UL 1977
Conditions of acceptability
Caution: Do not connect or disconnect under load. Metal housing parts shall be securely incorporated to protected ground.
* Remark for gold plated contacts: In order to avoid brittle inter-metallic connections, gold-plated terminals have to be tin-plated in the solder area.
34 IEC 60 664 ^= DIN VDE 0110 ; IEC 60 512-x ^= DIN EN 60 512-x
Amphenol