NPX1 Specifications
General
Operating Temperature
-40°F to 257°F (-40°C to 125°C)
3.0
.12
Storage Temperature
-67°F to 257°F (-55°C to 125°C)
10.3
.41
6.0
.24
Battery Supply Voltage
2.1 to 3.6 V (3.0 V typical)
Supply Current
600 nA typical power down current at 3.6 V
2.8
.11
Pressure Ranges
9.5
100 to 450, 100 to 700, 0 to 1400 is typical
.37
450 kPa Resolution
• 1.37 kPa/LSB (450 kPa to 100 kPa/255)
• -40°F to 257°F (-40°C to 125°C)
700 kPa Resolution
• 2.35 kPa/LSB (700 kPa to 100 kPa/255)
• -40°F to 257°F (-40°C to 125°C)
1400 kPa Resolution
• 5.49 kPa/LSB (1400 kPa to 0 kPa/255)
• -40°F to 257°F (-40°C to 125°C)
3.2
.13
1.5
.06
0.72
.028
1.27
.05
0.45
.018
CL
Over Pressure
10x
Pressure Measurement
Measurement Accuracy (2.1 to 3.6 V)
• -6 to 6 LSB (6Fcapability), 32°F to 122°F (0°C to 50°C)
• -8 to 8 LSB, -40°F to 257°F (-40°C to 125 °C)
Charge Consumption (All Pressure Ranges)
3.2 micro-coulombs; 77°F (25°C), 3V
Battery Voltage Measurement
• ±6 LSB, -40°F to 257°F (-40°C to 125°C)
• 1 LSB = 10.8 mV/LSB
• 0.4 micro-coulombs charge consumption
1.0
0.15
0.2
.04
.01
.008
NPX1 dimensions in [mm]
Pressure Measurement
Measurement Accuracy (2.1 to 3.6 V)
• -6 to 6 LSB (6 σ capability), 32°F to 122°F (0°C to 50°C)
• -8 to 8 LSB, -40°F to 257°F (-40°C to 125 °C)
Charge Consumption (All Pressure Ranges)
3.2 micro-coulombs; 77°F (25°C), 3V
Battery Voltage Measurement
• ±6 LSB, -40°F to 257°F (-40°C to 125°C)
• 1 LSB = 10.8 mV/LSB
• 0.4 micro-coulombs charge consumption