English
Language : 

NPA-300 Datasheet, PDF (2/8 Pages) Amphenol Corporation – Surface Mountable
Low Pressure NPA Specifications
Parameter
Value
Pressure Range
2 or 5
Maximum Overpressure
5X
Electrical @ 25°C (77°F) unless otherwise stated
Input Excitation
3.3 to 5.0
Environmental
Temperature Range
Units
Notes
In H2O
498 or 1245 Pa
Rated Pressure 400 in H2O Package Overpressure
VDC
3.1 to 5.25 VDC
Operating
-40 to +125
°C
-40 to +257°F
Compensated
0 to +60
°C
+32 to +140°F
Storage
Mechanical/Package
Weight
-40 to +125
~1
°C
grams
-40 to +257°F
Media Compatibility
Positive differential and gage ports
Media compatible with thermoset plastic, silicon, epoxy, RTV,
Pyrex, and UV silicone gel
Negative differential ports
Performance Parameters
Accuracy (Total Error Band)
Response Time
Current Consumption
Dry gasses only
Units
% Span
ms
mA
Minimum
-1.5
-2.5
Maximum
1.5
2.5
2
1.2
Notes
5”H2O Full Scale
2”H2O Full Scale
0.5 ms Typical
Typical
2