5.0 Electro-Optical Characteristics (25°C)
Table 4: Electro-Optical Characteristics (25°C)
Parameter
Number of photo detectors
Pixel-to-pixel spacing
Line scanning rate
Clock frequency(2)
Bright output voltage(3)
Bright output non-uniformity(4)
Adjacent pixel non-uniformity(5)
Dark non-uniformity(6)
Dark output voltage
Modulation transfer function(7)
Definitions:
Symbol
Tint(1)
f
Video output
Up
Uadj
Ud
Vd
MTF
Parameter
832
125
180
5
1.0
<+/-30
<25
<20
<200
>50
Units
Elements
µm
µsec
MHz
V
%
%
mV
mV
%
Note
Tested @ 5MHz
clock frequency
Test at Tint =
180us
See Note 7 for
MTF & DOF
1. Tint: Line scanning rate or integration time int is determined by the interval of two start pulses (SP). The module was test at 180us, but it will operate to 167us with
clocking speed of 5.0MHz.
2. f: main clock frequency he module was tested at 5.0MHz, but electrically it reliably operates above 5.0MHz, but with a minimum integration time of 167µsec.
3. Vpavg = ∑ Vp(n)/832
4. Up = [(Vpmax - Vp) / Vp] x 100% or [(Vp - Vpmin) / Vp] x 100%
5. Upadj = MAX[ | (Vp(n) - Vp(n+l) | / Vp(n)] x 100%
Upadj is the non-uniformity percentage pixel to pixel
6. Ud = Vdmax – Vdmin
Vdmin is the minimum output on a black document (O.D.=0.8)
Vdmax: maximum output voltage of black document (O.D.= 0.8)
7. MTF = [(Vmax - Vmin) / (Vmax + Vmin)] x 100 [%]. DOF range is defined with the MTF
MTF is measured at glass surface and at 0.4mm from the glass > 50 percent and peaks at approximately mid-point of 0.2mm.
Vmax: maximum output voltage at 50 lp/inch (At 1/2 of the optical Nyquest Frequency)
Vmin: minimum output voltage at 50lp/inch
8. O.D. = optical density
9. lp / inch: line pair per inch
Table 5: Recommended Operating Conditions (25°C)
Item
Symbol
Min.
Power supply
Vdd
4.5
Vn.
-4.5
VLED
Idd
In
ILED
Input voltage at digital high
Vih
Vdd-1.0
Input voltage at digital low
Vil
0
Clock frequency
f
Clock pulse high duty cycle
25
Clock pulse high duration
Integration time
Tint(3)
50
0.167
Operating temperature
Top
Notes:
1. Tested at 5.0MHz and 180us
2. Also used as test frequency
3. Tint (Min) is the lowest line integration time available at 5.0MHz clock rate
Mean(1)
5.0
-5
5
30
6
300
Vdd-.5
25
Max.
5.5
-12
5.5
40
15
450
Vdd
0.6
5.0(2)
5.0
50
Units
V
V
V
ma
ma
ma
V
V
MHz
%
ns
ms
°C
AMI Semiconductor – May 06, M-20561-001
4