5M1270ZT144C5N Datasheet, PDF (9/30 Pages) Altera Corporation – DC and Switching Characteristics for MAX V Devices | |||
|
◁ |
Chapter 3: DC and Switching Characteristics for MAX V Devices
3â9
Operating Conditions
Power-Up Timing
Table 3â15 lists the power-up timing characteristics for the MAX V device family.
Table 3â15. Power-Up Timing for MAX V Devices
Symbol
Parameter
Device
Temperature Range
Min Typ Max Unit
5M40Z
Commercial and industrial
Extended
â
â 200 µs
â
â 300 µs
5M80Z
Commercial and industrial
Extended
â
â 200 µs
â
â 300 µs
5M160Z
Commercial and industrial
Extended
â
â 200 µs
â
â 300 µs
tCONFIG
The amount of time from
when minimum VCCINT is
reached until the device
enters user mode (1)
5M240Z (2)
5M240Z (3)
5M570Z
Commercial and industrial
Extended
Commercial and industrial
Extended
Commercial and industrial
Extended
â
â 200 µs
â
â 300 µs
â
â 300 µs
â
â 400 µs
â
â 300 µs
â
â 400 µs
Commercial and industrial
5M1270Z (4)
Extended
â
â 300 µs
â
â 400 µs
Commercial and industrial
5M1270Z (5)
Extended
â
â 450 µs
â
â 500 µs
5M2210Z
Commercial and industrial
Extended
â
â 450 µs
â
â 500 µs
Notes to Table 3â15:
(1) For more information about power-on reset (POR) trigger voltage, refer to the Hot Socketing and Power-On Reset in MAX V Devices chapter.
(2) Not applicable to the T144 package of the 5M240Z device.
(3) Only applicable to the T144 package of the 5M240Z device.
(4) Not applicable to the F324 package of the 5M1270Z device.
(5) Only applicable to the F324 package of the 5M1270Z device.
May 2011 Altera Corporation
MAX V Device Handbook
|
▷ |