English
Language : 

EP5348UI Datasheet, PDF (3/12 Pages) Enpirion, Inc. – 400mA Synchronous Buck Regulator with Integrated Inductor
EP5348UI
Absolute Maximum Ratings
CAUTION: Absolute Maximum ratings are stress ratings only. Functional operation beyond the
recommended operating conditions is not implied. Stress beyond the absolute maximum ratings may
cause permanent damage to the device. Exposure to absolute maximum rated conditions for
extended periods may affect device reliability.
PARAMETER
Absolute Maximum Electrical Ratings
Supply Voltage – PVIN, AVIN, VOUT
Voltage on ENABLE
Voltage on VFB
ESD Rating (based on Human Body Mode)
ESD Rating (Charge Device Model)
Absolute Maximum Thermal Ratings
Maximum Operating Junction Temperature
Storage Temperature Range
Reflow Temp, 10 Sec, MSL3 JEDEC J-STD-020C
SYMBOL MIN MAX UNITS
VIN
-0.3
6.0
V
-0.3 VIN+ 0.3
V
-0.3
2.7
V
2000
V
500
V
TJ-ABS
150
°C
TSTG
-65
150
°C
260
°C
Recommended Operating Conditions
PARAMETER
Input Voltage Range
Output Voltage Range
Operating Ambient Temperature
Operating Junction Temperature
SYMBOL
VIN
VOUT
TA
TJ
MIN
2.5
0.6
-40
-40
MAX
5.5
V IN- V DO†
+85
+125
UNITS
V
V
°C
°C
† VDO (drop-out voltage) is defined as (ILOAD x Dropout Resistance). Please see the EC Table.
Thermal Characteristics
PARAMETER
Thermal Shutdown Trip Point
Thermal Shutdown Trip Point Hysteresis
Thermal Resistance: Junction to Ambient –0 LFM (Note 1)
SYMBOL
TJ-TP
θJA
TYP
+155
15
105
Note 1: Based on 2 oz. external copper layers and proper thermal design in line with
EIA/JEDEC JESD51-7 standard for high effective thermal conductivity boards.
UNITS
°C
°C
°C/W
05721
3
October 11, 2013
www.altera.com/enpirion
Rev D