English
Language : 

RDC10_15 Datasheet, PDF (4/6 Pages) ALPS ELECTRIC CO.,LTD. – The high accuracy space saving design contributes to reduced weight and size of sets
Resistive Position Sensors / Product Specifications
 Method for Regulating the Linearity
Model RDC40
11.. RReeffeerreennccee ttaappeerr :: 9900%%//1133rroottaattiioonnss
22.. VVAA iiss mmeeaassuurreedd oouuttppuutt vvaalluuee
110000
VVAA
55
00 00
1133 rroottaattiioonnss
Model RDC50 / RDC90 / RD6R1A / RDCC0
1. Reference taper:100%/A
2. Index point is 50% output point(RDC50/RDC90/RDCC0)
The center is in the configuration diagram condition
100
50
0
Series
RDC50
RDC90
RD6R1A
RDCC0
0˚
B
A
333.3°
80°
260°
320°
30°
B
±160°
±30°
±122°
±155°
±15°
C
±2%
±3%
±2%
±2%
Model RDC80
1. Reference taper : 100% / 340˚
2. The center is in the configuration diagram condition
2T output
4T output
100
180˚(phase difference)
±165˚
50
±165˚
0
0˚
center
Model RDC10 / RD7
With rated voltage applied between terminals 1 and 3, the straight line which
connects the measured output values VB and VA at specified reference positions
B and A is assumed to be an ideal straight line, so that deviation against the ideal
straight line when the voltage applied between terminals 1 and 3 is assumed to be
100% can be expressed as a percentage.
VA
Position B
Position A
Ê¢.FDIBTUSPLFÊ£
VB
B
A
Resistive Position Sensors / Measurement and Test Methods
Resistive Position Sensor
〔Total Resistance〕
The total resistance, with the shaft(lever)placed at the end of terminal 1 or 3, shall be determined by
measuring the resistance between the resistor terminals 1 and 3 unless otherwise specified.
〔Rating Voltage〕
The rating voltage corresponding to the rated power shall be determined by the following equation. When the
resulting rated voltage exceeds the maximum operating voltage of a specific resistor, the maximum operating
voltage shall be taken as the rated voltage.
E=√ P・R
E:Rated voltage(V)
P:Rated powe(r W)
R:Total nominal resistance(Ω)
477