English
Language : 

SKRH Datasheet, PDF (3/3 Pages) ALPS ELECTRIC CO.,LTD. – 4-direction with Center-push Function (Surface mount type)
Switch Type Multi Control Devices
Soldering Conditions
Multi Control
Devices
Example of Reflow Soldering Condition
1. Heating method:
Double heating method with infrared heater.
2. Temperature measurement: Thermocouple 0.1 to 0.2П CAʢKʣor CCʢTʣat solder joints copper foil surfaceʣ. A heat resistive tape
should be used to fix thermocouple.
3. Temperature profile
300
200
100
Room
temperature
Pre-heating
F max.
A max.
B
D
E
Time (s)
C
Variable
Resistor Type
Switch
Type
Serieʢ s Reflow typeʣ
RKJXS
SLLB, SLLB5
SKRV/SKRH/SKQUBA,DB/SSAF/SRBE
Aʢˆʣ
3s max.
260
240
260
Bʢˆʣ
230
Cʢsʣ
40
20
40
Dʢˆʣ
150
180
Eʢˆʣ
150
Fʢsʣ
120
Notes
1. The above temperature shall be measured on the mounting surface of a PC board. There are cases where the PC
board's temperature greatly differs from that of the switch, depending on the material, size thickness of PC boards
and others. The above-stated conditions shall also apply to switch surface temperatures.
2. Soldering conditions differ depending on reflow soldering machines. Prior verification of soldering condition is
highly recommended.
492