English
Language : 

45106 Datasheet, PDF (1/2 Pages) Alpha Wire – 6 Components Cabled
Part Number: 45106
Page 1 of 2 Pages
A. Construction
1) Component 1
a) Conductor
b) Insulation
(1) Color Code
ALPHA WIRE
CUSTOMER PRODUCT SPECIFICATION
Issue:
Issue Date:
Effective Date:
15
1/19/2015
1/31/2015
6 X 1 COND
22 (7/30) AWG Tinned Copper
0.016" Wall, Nom. TPE
Alpha Wire Color Code E
Diameters (In)
0.030
0.062
Cond
1
2
Color
BLACK
BROWN
Cond
3
4
Color
RED
ORANGE
Cond
5
6
Color
YELLOW
GREEN
2) Cable Assembly
6 Components Cabled
a) Twists:
b) Core Wrap
6.0 Twists/foot (min)
Nonwoven Polyester Tape, 25% Overlap, Min.
3) Shield:
a) Drain Wire
A/P/A Tape, 25% Overlap, Min.
22 (7/30) AWG Tinned Copper
b) Braid
4) Jacket
Tinned Copper,70% Coverage, Min.
0.045" Wall, Nom.,TPE
0.309 (0.322 Max.)
a) Color(s)
b) Ripcord
Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
1 End 810 Denier Nylon
c) Print
ALPHA WIRE-* P/N 45106 6C 22 AWG
XTRAGUARD(R) 4 (UL) TYPE PLTC 105C SUN RES OR AWM
20237/21918 125C 300 V OR
CRU AWM I/II A/B 125C 300 V FT1
P-07-KA140023-MSHA
(SEQ FOOTAGE)
CE ROHS
* = Factory Code
B. Applicable Specifications
1) UL
AWM/STYLE 20237
PLTC
125°C / 300 VRMS
105°C
AWM/STYLE 21918
SUN RES
125°C / 300 VRMS
2) CSA International
C(RU) AWM I/II A/B FT1
SUN RES (Black only)
125°C / 300 VRMS
3) Other
4) CE:
PENNSYLVANIA BUREAU OF MINE SAFETY APPROVED
EU Low Voltage Directive 2006/95/EC
C. Environmental Compliance
1) CE:
EU Directive 2011/65/EU(RoHS2):
This product complies with European Directive 2011/65/EU (RoHS Directive) of the
European Parliament and of the Council of 8 June 2011. No Exemptions are
required for RoHS Compliance on this item. Consult Alpha Wire's web site for
RoHS C of C.
2) California Proposition 65: The outer surface materials used in the manufacture of this part meet the
requirements of California Proposition 65.
D. Physical & Mechanical Properties
1) Temperature Range
-50 to 125°C
2) Bend Radius
3) Pull Tension
10X Cable Diameter
43 Lbs, Maximum
4) Sunlight Resistance
E. Electrical Properties
1) Voltage Rating
2) Capacitance
Yes
(For Engineering purposes only)
300 VRMS
20.2 pf/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance
4) Inductance
36 pf/ft @1 kHz, Nominal
0.2 µH/ft, Nominal
5) Conductor DCR
6) OA Shield DCR
16.5 Ω/1000ft @20°C, Nominal
2.9 Ω/1000ft @20°C, Nominal
Although Alpha Wire Company ("Alpha") makes every reasonable effort to ensure their accuracy at the time of publication, information and specifications
described herein are subject to errors or omissions and to changes without notice, and the listing of such information and specifications does not ensure
product availability.
Alpha provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In
no event will Alpha be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary) whatsoever, even if Alpha has
been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the
use, or inability to use, the information or specifications described herein.
711 Lidgerwood Ave Elizabeth, NJ 07207-0711
Toll Free 1-800-52 ALPHA • T: 1-908-925-8000 • F: 908-925-5411 • Email: info@alphawire.com
www.alphawire.com