English
Language : 

AP134-501 Datasheet, PDF (4/5 Pages) Alpha Industries – Tri-Band HBT Power Amplifier Module
Tri-Band HBT Power Amplifier Module
AP134-501
All data taken under CW conditions and include 0.2 dB of input and output fixture losses deembedded, GSM class 4 pulsed
performance adds 0.5 dB of output power and 5–7% in PAE.
40
70
30
POUT @ VCC = 4.2
60
20
50
POUT @ VCC = 3.2
10
POUT @
0
VCC = 2.8
40
PAE @
VCC = 3.2
30
-10
20
-20
PAE @
VCC = 4.2
10
-30
0
-40
PAE @ VCC = 2.8
-10
0
0.5
1.0
1.5
2.0
VAPC (V)
POUT and PAE vs. VCC and VAPC
PIN = 6 dBm
40
60
POUT 75˚C
30
50
POUT -25˚C
20
40
POUT 25˚C
10
30
0
20
PAE 75˚C
-10
10
PAE 25˚C
-20
-30
0
0
PAE -25˚C
-10
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Control Voltage – VAPC (V)
POUT and PAE vs. Temperature
VCC = 3.2 V, PIN = 6 dBm,
Frequency = 880 MHz
40
POUT 75˚C
30
POUT 25˚C
20
POUT -25˚C
10
0
-10
60
50
40
PAE 75˚C 30
PAE 25˚C 20
PAE -25˚C
10
-20
0
-30
-10
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Control Voltage – VAPC (V)
POUT and PAE vs. Temperature
VCC = 3.2 V, PIN = 6 dBm,
Frequency = 1710 MHz
40
60
POUT 75˚C
30
50
POUT 25˚C
20
40
10
POUT -25˚C
30
0
20
PAE -25˚C
-10
10
-20
-30
0
PAE 25˚C
0
PAE 75˚C
-10
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Control Voltage – VAPC (V)
POUT and PAE vs. Temperature
VCC = 3.2 V, PIN = 6 dBm,
Frequency = 1850 MHz
36.0
35.8
35.6
35.4
35.2
35.0
34.8
34.6
34.4
34.2
34.0
0
60
59
58
57
POUT 56
55
54
53
PAE
52
51
50
20
40
60
80
100
Duty Cycle (%)
40
30
20
10
0
-10
-20
-30
-40
-50
0
F0 (dBm)
2 F0 (dBm)
3 F0 (dBm)
0.5
1.0
1.5
2.0
VAPC (V)
Duty Cycle Effects on Module Performance
VCC = 3.2 V, Frequency = 900 MHz,
PIN = 6 dBm
Harmonic Performance VCC = 3.2 V,
Frequency = 900 MHz, PIN = 6 dBm
4
Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 • Email sales@alphaind.com • www.alphaind.com
Specifications subject to change without notice. 8/01A