AT002N5-11 Datasheet, PDF (1/2 Pages) Alpha Industries – GaAs 50 dB IC Voltage Variable Dual Control Attenuator DC-3 GHz | |||
|
GaAs 50 dB IC Voltage Variable
Dual Control Attenuator DCâ3 GHz
AT002N5-11
Features
I Dual Control Voltages
I Low Insertion Loss
I 8 Lead Hermetic Surface Mount Package
I Capable of Meeting MIL-STD
Requirements5
Description
The AT002N5-11 is a GaAs IC FET absorptive
attenuator. This device provides up to 50 dB variable
attenuation from DCâ3 GHz. Attenuation can be
controlled by varying each of the two control bias voltages
from 0 to -5 V. This attenuator is recommended for fast
response AGC circuits in commercial and high reliability
applications.
-11
ORIENTATION
MARK
0.180 (4.57 mm)
SQ. MAX.
0.150
(3.81 mm)
0.050
0.400 (10.16 mm)
0.380 (9.65 mm)
0.017 (0.43 mm)
0.013 (0.33 mm)
(1.27 mm)
TYP.
0.070 (1.78 mm)
0.040 (1.02 mm)
0.006 (0.15 mm)
0.004 (0.10 mm)
0.075
(1.91 mm)
MAX.
0.250 (6.35 mm)
0.200 (5.08 mm)
Electrical Specifications at 25°C
Insertion Loss2
Parameter1
Attenuation Range
VSWR (I/O)
Frequency4
DCâ1.0 GHz
DCâ2.0 GHz
DCâ3.0 GHz
DCâ1.0 GHz
DCâ2.0 GHz
DCâ3.0 GHz
DCâ1.0 GHz
DCâ2.0 GHz
DCâ3.0 GHz
Min.
Typ.
Max. Unit
1.2
1.4
dB
1.4
1.8
dB
1.7
2.0
dB
50
52
dB
45
48
dB
40
42
dB
1.2:1
1.4:1
1.6:1
1.3:1
1.5:1
1.8:1
Operating Characteristics at 25°C
Parameter
Switching Characteristics
Input Power for 1 dB Compression
Condition
Rise, Fall (10/90% or 90/10% RF)
On, Off (50% CTL to 90/10% RF)
Video Feedthru3
For All Attenuation Levels
Control Voltages
VLow = 0 to -0.2 V @ 20 µA Max.
VHigh = -5 V @ 100 µA Max.
1. All measurements made in a 50 ⦠system, unless otherwise specified.
2. Insertion loss changes by 0.003 dB/°C.
3. Video feedthru measured with 1 ns risetime pulse and 500 MHz bandwidth.
4. DC = 300 kHz.
5. See Quality/Reliability section.
Frequency
0.5â3 GHz
0.05 GHz
Min.
Typ.
10
15
20
0
-3
Max.
Unit
ns
ns
mV
dBm
dBm
Alpha Industries, Inc. [781] 935-5150 ⢠Fax [617] 824-4579 ⢠Email sales@alphaind.com ⢠www.alphaind.com
1
Specifications subject to change without notice. 6/00A
|
▷ |