PCSD054 Datasheet, PDF (1/1 Pages) Allied Components International – Shielded Power Chip Inductor | |||
|
RoHS
Shielded Power Chip Inductor PCSD054
Dimensions: Inches
(mm)
0.307±0.014
(7.8±0.35)
0.276±0.014
(7.0±0.35)
XXX
0.118±0.016
(4.5±0.40)
Allied
Part
Number
Inductance Tolerance
(µh)
(%)
Test
Freq.
KHz, 0.1V
PCSD054-100M-RC
10
20
100
PCSD054-120M-RC
12
20
100
PCSD054-150M-RC
15
20
100
PCSD054-180M-RC
18
20
100
PCSD054-220M-RC
22
20
100
PCSD054-270M-RC
27
20
100
PCSD054-330L-RC
33
15
100
PCSD054-390L-RC
39
15
100
PCSD054-470L-RC
47
15
100
PCSD054-560K-RC
56
10
100
PCSD054-680L-RC
68
15
100
PCSD054-820L-RC
82
15
100
PCSD054-101K-RC 100
10
100
PCSD054-121K-RC 120
10
100
PCSD054-151K-RC 150
10
100
PCSD054-181K-RC 180
10
100
PCSD054-221K-RC
220
10
100
PCSD054-271K-RC
270
10
100
Tolerance: also available in: K=10% and M=20%
All specifications subject to change wtihout notice.
RDC
(â¦)
Max.
0.07
0.07
0.08
0.10
0.13
0.16
0.18
0.18
0.27
0.29
0.33
0.43
0.49
0.68
0.94
1.00
1.18
1.30
Rated
Current
(A)
1.65
1.57
1.39
1.29
1.12
1.06
0.97
0.91
0.80
0.76
0.68
0.62
0.55
0.49
0.44
0.40
0.36
0.33
UNIT: mm
Features
⢠SMD Power Inductor
⢠Magnetically shielded
⢠Low DC resistance
⢠High Current
⢠Ideal for DC-DC converter applications
Electrical
Inductance Range: 10µh to 270µh,
Available in additional values
Tolerance: As shown in the table.
Also, available in tighter tolerances
Operating Temp: -40ºC ~ +100ºC
Rated Current: Current at which inductance
drop by no more than 10% of intial value or the
temperature has risen by 40ºC which ever occurs first
Test Equipment
(L): HP4284 A LCR Meter
(RDC): CH502BC or equal
Physical
Packaging: 800 pieces per 13 inch reel.
Marking: EIA Inductance Code
714-665-1140
ALLIED COMPONENTS INTERNATIONAL
07/03/1151
www.alliedcomponents.com
|