2032-C0023PX-23B Datasheet, PDF (4/9 Pages) Allen-Bradley – ElectroGuard
Safety Isolation System
ElectroGuard
Combination Systems with Fusible Disconnect Switch
Product Selection for Outside North America (see page 12-19 for Ordering Instructions)
3-Phase Max. kW Rating
(50Hz)
Catalogue Number ➋
Ampere
Rating
(AC-3)
630
Fuse Clip
Rating/
230V 400V 500V 600V Type ➊ IP 30 Enclosure
630A DIN 2032*-C0630P⊗-30D
200 355 450 500 800A BS 88 2032*-C0630P⊗-31B
1600A DIN 2032*-C0630P⊗-31D
800A BS 88 2032*-C0860P⊗-31B
IP 54 Enclosure
2032*-C0630H⊗-30D
2032*-C0630H⊗-31B
2032*-C0630H⊗-31D
2032*-C0860H⊗-31B
IP 54 Motor Control
Centre Type
Enclosure (with
bussing)
2032-!0630H⊗30D
2032-!0630H⊗-31B
2032-!0630H⊗-31D
2032-!0860H⊗-31B
IP 65 Enclosure
2032*-C0630W⊗-30D
2032*-C0630W⊗-31B
2032*-C0630W⊗-31D
2032*-C0860W⊗-31B
860
250 500 560 600
1250A
BS 88
2032*-C0860P⊗-32B 2032*-C0860H⊗-32B
2032-!0860H⊗-32B
2032*-C0860W⊗-32B
1600A DIN 2032*-C0860P⊗-31D 2032*-C0860H⊗-31D 2032-!0860H⊗-31D 2032*-C0860W⊗-31D
1200
391
710
888 1043
1250A
BS 88
2032*-C1200P⊗-32B 2032*-C1200H⊗-32B
2032-!1200H⊗-32B 2032*-C1200W⊗-32B
1600A DIN 2032*-C1200P⊗-31D 2032*-C1200H⊗-31D 2032-!1200H⊗-31D 2032*-C1200W⊗-31D
To order the Time Delay feature, add the following Cat. String to the end of the Catalogue Number shown in the table:
Factory set 30 second time delay feature:
-1TD
Example: Catalogue Number 2032-C0180P⊗-29B becomes Catalogue Number 2032-C0180P⊗-29B-1TD to include the time delay feature.
* Input Power Feed Catalogue Number Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Example: Catalogue Number 2032*-C0630P⊗-31B becomes Catalogue Number 2032T-C0630P⊗-31B for a “Top Feed” input power requirement.
Input Power Feed
Top Feed
Bottom Feed
Catalogue Number Code
T
B
! Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Catalogue Number 2032-!0085H⊗-27D becomes Catalogue Number 2032-E0085H⊗-27D for “600A Line Side Incoming Bus and Outgoing Power
Cables” bussing designation.
Type of Bussing ➌
Catalogue Number Code
600A Line Side Incoming Bus and Outgoing Power Cables
E
1200A Line Side Incoming Bus and Outgoing Power Cables
D
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
H
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
R
⊗ Input Line Voltage Code
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Example: Catalogue Number 2032-C0085W⊗-26B becomes Catalogue Number 2032-C0085WN-26B for a 380V 50Hz Input Line Voltage application.
Input Line Voltage
220V 50Hz 380-400V 50Hz 400-415V 50Hz 440V 50Hz 500V 50Hz 550V 50Hz
Voltage Code for Catalogue Number
A
N
G
B
M
C
Product Selection: Remote Lockout Station ➍
Catalogue Number
“System Isolated” Light Colour
IP 30 Enclosure
IP 54 Enclosure
IP 65 Enclosure
Green
2030-RLSPG
2030-RLSHG
2030-RLSWG
➊ Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.
➋ Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position.
Consult your local Rockwell Automation sales office for other time settings.
➌ Bus Type: Copper with tin plating. Consult factory for other types of bussing.
➍ Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
12-9