English
Language : 

GD2 Datasheet, PDF (2/2 Pages) Allen-Bradley – Non contact Switches
Interlock Switches
Non contact Switches
Ferrogard GD2
Product Selection
Safety Contact
Switching Capability Safety Contacts Auxiliary Contacts Connection
Housing
Material
1 N.C.
1 N.O.
250V AC 2A
2 N.C.
None
1 N.C.
1 N.O.
3m Cable
Stainless Steel
24V DC 1A
2 N.C.
None
1 N.O.
Note: Contacts are described with the guard door closed, that is, actuator in place. Switch is shipped with complete actuator.
Type
FRS 2 GD2
FRS 20 GD2
FRS 21 GD2
FRS 2 GD2
FRS 20 GD2
FRS 21 GD2
Catalogue Number
440N-G02112
440N-G02113
440N-G02117
440N-G02118
440N-G02119
440N-G02123
Accessories
Actuator
Description
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
Switch
4.4
(0.17)
8
(0.31)
6 (0.24)
8 (0.31)
Page Number
—
Catalogue Number
440N-A02128
Actuator
33.5 (1.32)
8 (0.31) 16.75 (0.66)
16 (0.63)
11.5
(0.45)
11.5
(0.45)
5
(0.20)
5
(0.20)
7 (0.28)
19.5
(0.77)
16.75 (0.66)
33.5 (1.32)
16
(0.63)
7
(0.28)
19.5
(0.76)
4.4 (0.17)
Typical Wiring Diagrams
FRS 2
FRS 21
Red Safety N.C.
Fuse
Externally
Blue
Yellow
Aux.
N.O.
Green
Blue
Red
Black
White
FRS 20
Yellow
Red Safety N.C.
Fuse
Externally
Blue
Green
Black
White
Safety N.C.
Fuse
Externally
Note: Unit must be to a grounded to a grounded metal frame or grounded via the field wiring per NEC requirements.
Safety N.C.
Fuse
Externally
Safety N.C.
Fuse
Externally
Aux.
N.O.
Application Details
See page 3-54 for operating principles and mounting examples.
3-51