MSR38D Datasheet, PDF (1/2 Pages) Allen-Bradley – Monitoring Safety Relays with Delayed Outputs
Safety Relays
Monitoring Safety Relays with Delayed Outputs
Minotaur MSR38D/DP
Specifications
Housing with removable
terminals shown.
Description
The Minotaur MSR38D/DP is a microprocessor-based, monitoring
safety relay, with delayed, safety-rated, solid state outputs.
The inputs of the MSR38D/DP are the same as the MSR30. They
can be connected to gate interlocks, e-stop devices or 4-wire safety
mats. The gate interlocks and e-stops can be either single channel or
dual channel normally-closed circuits.
The reset capability of the MSR38D/DP allows it to set up for
manual or automatic start and restart.
The outputs include two delayed normally-open safety rated outputs
that can be connected to loads up to 2A at 24V DC. These outputs
can be used to send a safety stop signal to a machine or
manufacturing system. The delay is accomplished by the
configuration of jumpers on the terminals. The delay can be easily
adjusted by reconfiguring the jumpers.
The MSR38D/DP also has one solid state normally-closed auxiliary
output, which must only be used to indicate the status of the
MSR38D/DP. The auxiliary output responds immediately to the
change in input status; it is not delayed.
Features
• Cat. 4 per EN954-1
• Stop Category 0 or 1
• 2 Delayed Solid State Safety Outputs
• 1 Solid State Auxiliary Output
• 1 N.C., 2 N.C. or Safety Mat Input
• Monitored Manual or Automatic/Manual Reset
Standards
EN954-1, ISO13849-1, IEC/
EN60204-1, ANSI B11.19,
AS4024.1
Safety Category
Cat. 4 per EN954-1 (ISO13849-1)
Approvals
CE for all applicable directives, C-
Tick, cULus, TUV
Power Supply
24V DC SELV
Power Consumption
3W
Safety Inputs
1 N.C.
Max. Allowable Input Resistance 200 ohms
Outputs
2 N. O. Safety,
1 N.C. Aux,
Output Rating Safety
Auxiliary
2A @ 24V DC
50mA @ 24V DC
Fuses, Output External
6A slow blow or 10A quick blow
Power On Delay
3s
Response Time
15ms
Recovery Time
20ms
Indication LEDs
Green = Power (Pwr)
Green = K1 Closed
Green = K2 Closed
Pwr LED 3s Blink
Diagnostics Constant
2 Blinks
4 Blinks
Continuous Blinking
Initialization
Normal operation
Config. change during operation
Solid state output switch fault
Internal Fault
Operating Temperature
-5°C to +55°C (+14° to +131°F)
Humidity
90% RH
Enclosure Protection
IP40 (NEMA 1), DIN 0470
Terminal Protection
IP20, DIN 0470
Pollution Degree
2
Conductor Size
0.2 – 2,5mm2 (24 – 14AWG)
Mounting
35mm DIN rail
Weight
130g (0.287 lbs)
Vibration
10-55Hz, 0.35mm
Shock
10g, 16ms, 100 shocks
➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not
shown.
Wiring Terminations
S11 & S21
S12 & S22
A1 – S34
S11 – S34
S21 – S34
A1 – Y2
A1 – Y41
Pulse train output
Input contacts
Reset switch
Automatic reset, start-up test disabled
Automatic reset, start-up test enabled
Monitoring circuit
Cross-fault monitoring disabled
4-46