Description
The Minotaur MSR132E is a monitoring safety expansion relay unit
with single or dual channel input and either immediate or timed off-
delay outputs. It is designed to be operated as an “extension” of a
“master” safety relay. When wired properly, the outputs of the
MSR132E will mimic the outputs of the master relay.
The outputs include 4 normally open safety rated outputs used to
shut down the manufacturing system and 2 normally closed auxiliary
outputs to indicate status of the MSR132E. One additional normally
closed output is available to allow the host relay to monitor the
status of the MSR132E. The safety, auxiliary and monitoring outputs
have independent and redundant internal contacts to help ensure the
safety function.
Features
• Category 4/3 per EN 954-1
• Stop Category 0 or 1
• 4 Safety contacts N.O.
• 2 Auxiliary contacts N.C.
• 1 Monitoring contact N.C.
• Single channel input
Specifications
Standards
EN 954-1, ISO 13849-1, IEC/EN
60204-1, IEC 60947-5-1, ANSI
B11.19, AS4024.1
Category Instantaneous/Delayed Cat. 4/Cat. 3 per EN 954-1
Approvals
C-Tick, CE marked for all
applicable directives, cULus and BG
Power Supply
24V AC/DC 50/60Hz or 24VDC
0.85 to 1.1
Power Consumption
1.5W
Safety Inputs
1 N.C.
Outputs
4 N. O. Safety,
2 N.C. Aux,
1 N.C. Monitoring
Output Utilization per IEC
60947-4-1 (Resistive)
AC-1: 6A/250V AC
DC-1: 3A/24V DC
➊ Output Utilization per IEC
60947-5-1 (Inductive)
B300, AC-15
6A/250V AC, 6A/125VAC
P300, DC-13
3A/24V DC
Thermal Current (non switching) 2x6A, 3x5A, 4x 4A
Fuses, output external
6A slow blow or 10A quick blow
Minimum Switched Current/
Voltage
10mA/10V
Contact Material
AgSnO2 + 2µAu
Power On Delay
100ms
Response Time
50ms
Recovery Time
100ms
Indication LEDs
Green = K1 Closed
Green = K2 Closed
Impulse Withstand Voltage
2500V
Operating Temperature
-5°C to +55°C (+14° to +131°F)
Humidity
90% RH
Enclosure Protection
IP40 (NEMA 1), DIN 0470
Terminal Protection
IP20, DIN 0470
Pollution Degree
2
Conductor size
0.2 - 4mm2 (24 - 12AWG)
Mounting
35mm DIN rail
Weight
215g (0.474 lbs)
Electrical Life (w/Surge Supp.)
250V AC/6A/1250VA cosϕ=1
250V AC/2A/500VA cosϕ=1
250V AC/4A/1000VA cosϕ=0.35
250V AC/1.5A/1000VA cosϕ=0.6
24V DC/2A/48W
10V DC/0.01A/0.1W
100,000 operations
500,000 operations
300,000 operations
100,000 operations
1,000,000 operations
2,000,000 operations
Mechanical Life
2,000,000 operations
Vibration
10-55Hz, 0.35mm
Shock
10g, 16ms, 100 shocks
➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not
shown.