English
Language : 

FRS3 Datasheet, PDF (1/2 Pages) Allen-Bradley – Non contact Switches
Interlock Switches
Non contact Switches
Ferrogard 3, 4 & 5
Description
The Ferrogard range of magnetically actuated switches offers non
contact reliability together with tolerance to misalignment. They are
designed to be installed so that when a guard door is opened, the
action of the magnetic actuator being removed from the switches
opens the N.C. safety contacts which are intended for the isolation
of control power to a machine primary control element.
The FRS 3, 4 and 5 have terminal connections. The user must drill a
hole in the housing at a convenient location to allow the wiring to
enter the housing. The cover is secured with anti-tamper security
screws.
Unlike some magnetic switches the Ferrogards have protected safety
contacts to help ensure that they do not fail to danger. In addition,
some versions have independent auxiliary signal contacts to indicate
the guard condition.
All Ferrogards have internal non-resettable overload protection on
the safety contact. They should be protected by an external fuse
rated as shown in the specifications table.
Features
• Non contact actuation
• High tolerance to misalignment
• High switching current (up to 2A)
• Various contact arrangements
• Terminal connections
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119,
ANSI B11.19, AS4024.1
Category
Cat. 1 Device per EN954-1
Dual channel interlocks suitable for Cat.
3 or 4 systems
Approvals
CE marked for all applicable directives
and cULus
Reed Contacts
Safety Auxiliary
Operating Distance – Make
FRS3 12mm (0.47in) 21mm (0.83in)
FRS4 12mm (0.47in) 13mm (0.51in)
FRS5 12mm (0.47in) NA
Operating Distance – Break
FRS3
FRS4 23mm (0.91in) 24mm (0.94in)
FRS5 23mm (0.91in) 10mm (0.39in)
12mm (0.47in) NA
Closing Time
3.0ms 0.5ms
Dropout Time
2.1ms 0.3ms
Bounce Time
0.7ms 0.7ms
Initial Contact Resistance 15mΩ
10mΩ
Initial Capacitance, Terminal 0.65pF 0.2pF
to Terminal
Initial Insulation Resistance 1.x.106 Ω
Terminal to Terminal
1x106 Ω
Safety Contact Switching
Capability
250V AC 2A max
Safety Contact External
Fusing
≤1.6A quick blow
Auxiliary Contact Switching 300V DC, 250V AC, 0.5A including
Capability
inrush. 15VA/10W suitable for AC/DC
circuits
Min Initial Breakdown
Voltage
600V AC 600V AC
Operating Temperature
-10°C to +65°C (14° to 149°F)
Enclosure Protection
IP65 (NEMA 13)
Case Material
Red moulded ABS Plastic
Mounting
Any Position
M4 mounting security screws included.
Electrical Life
1 x 106 at rated loaded
Mechanical Life
10 x 106
Vibration
10 to 200Hz
Shock
50g
3-46