English
Language : 

802T-ATPD Datasheet, PDF (1/4 Pages) Allen-Bradley – Safety Limit Switches
Position Interlock Switches
Safety Limit Switches
802T Direct Opening Action NEMA-Style Switches
Specifications
Standards
Category
Approvals
Enclosure Rating
Operating Temperature
Cable Versions Temperature
Storage Temperature
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119, IEC/
EN60947-5-1, ANSI B11.19, AS4024.1
Cat. 1 Device per EN954-1
Dual channel interlocks suitable for Cat.
3 or 4 systems
cULus listed, CE marked for all
applicable directives and TUV for 2-
circuit models
NEMA 4, 6P, 12, 13 and IP67
-18°C to +110°C (0°F to +230°F)
-18°C to 60°C (0°F to 140°F)
-40°C to 121°C (-40°F to 250°F)
Description
Bulletin 802T Direct Opening Action limit switches have been
designed for use in control reliable applications and safety
applications per ISO 14119. These limit switches utilize the same
mounting dimensions as other NEMA style limit switches. The
rugged metal construction and plug-in body are designed for use in
harsh industrial environments.
Direct Opening Action assures that the normally closed contacts
open when the limit switch is actuated. This opening will occur even
in the event of a contact weld condition, up to 10 Newtons.
ATTENTION: To ensure that the normally
closed (safety) contacts open, the limit
switch actuator must be displaced beyond
the point of Direct Opening Action (see
specifications).
Features
• Direct opening action
• Snap acting contacts
• Rugged metal construction
• Long life and reliability
• Plug-in design
• NEMA 6P/IP67 sealing
Typical Applications
• Machine guards
• Access gates and doors
• Cranes or hoists
• Transfer stations
• Indexing tables
• Robotic cells
AC Contact Rating
(Maximum per Pole, 50 or 60Hz, 2 Circuits)
NEMA
Rating
Designation
A600
AC-15
Max
Max
Voltage
120
240
480
600
A
Make Break
60 6.00
30 3.00
15 1.50
12 1.20
Continuous
Carrying
Current
10
10
10
10
VA
Make Break
7200 720
7200 720
7200 720
7200 720
AC Contact Rating
(Maximum per Pole, 50 or 60Hz, 4 Circuits)
NEMA
Rating
Designation
A300
Max
Max
Voltage
120
240
A
Make Break
60 6.00
30 3.00
Continuous
Carrying
Current
10
10
VA
Make Break
7200 720
7200 720
DC Contact Rating (Maximum per Pole)
NEMA
Rating
Designation
Q300
Q300
DC 13
Max
Voltage
250
125
A
Make Break
0.27 0.27
0.55 0.55
Continuous
Carrying
Current
2.5
2.5
VA
Make Break
69 69
69 69
Low Voltage DC
24V DC @ 1.1 Amps resistive load
802T Operating Levers
See the Limit Switches section of the Sensors catalogue.