English
Language : 

A1181 Datasheet, PDF (6/14 Pages) Allegro MicroSystems – Two-Wire, Programmable, Chopper-Stabilized, Unipolar Hall-Effect Switch
TWO-WIRE, PROGRAMMABLE, UNIPOLAR HALL-EFFECT SWITCH FAMILY
(PRELIMINARY INFORMATION – SUBJECT TO CHANGE)
PROGRAMMING PROTOCOL
The operate points are programmed by serially addressing the devices through the supply terminal VCC (pin 1). After the
correct operate point is determined, the device programming bits are permanently blown, and a locking bit is blown to
prevent any further programming.
Switch Point Program Enable. To program the device, a keying sequence is used to activate / enable the addressing
mode as shown in Figure 1. This sequence consisting of a VPP pulse, one VPH pulse, and a VPP pulse with no supply
interruptions, is designed to prevent the device from being programmed accidentally (e.g., as a result of noise on the
supply line).
Figure 1. Program Enable Pulse Sequence.
Valid over operating temperature range unless otherwise noted.
Part Number
Characteristics
PROGRAMMING PROTOCOL (TA = +25 °C)
Programming Voltage6
Programming Current
A118X Family
Pulse width
Pulse Rise Time
Pulse Fall Time
Symbol
Test Conditions
Min.
VPL
Minimum voltage range
during programming
4.5
VPH
11.5
VPP
25
IPP
tr = 11us, 5V→26V,
Cbypass = 0.1uF
-
td(0) OFF time between bits
20
Pulse duration for enable
td(1) and addressing
20
sequences
tdP
Pulse duration for fuse
blowing
100
tr
VPL to VPH or VPP
5
tf
VPH or VPP to VPL
5
Limits
Typ. Max.
Units
5
5.5
V
12.5 13.5
V
26
27
V
190
-
mA
-
-
µs
-
-
µs
300
-
µs
-
100
µs
-
100
µs
6 Programming Voltages are measured at Pin #1 (Vcc) of SIP. A minimum capacitance of 0.1uF must be connected from Vcc to GND of the SIP to
provide the current necessary to blow the fuse.
Rev. 1.8 25 April 2003
Page 6
115 Northeast Cutoff, Box 15036
Worcester, Massachus etts 01615-0036 (508) 853-5000
Copyright © 1993, 1995 Allegro MicroSystems, Inc.