English
Language : 

A5303_16 Datasheet, PDF (5/15 Pages) Allegro MicroSystems – Photoelectric Smoke Detector with Interconnect, Timer, and Latching Alarm Indicator
A5303
Photoelectric Smoke Detector
with Interconnect, Timer, and Latching Alarm Indicator
AC ELECTRICAL CHARACTERISTICS (continued)1 Valid at TA = 25°C, VDD = 2.3 to 5.5 V, configured as in Typical Application
Diagram (unless otherwise noted)
Characteristics
Symbol
Test Conditions
OSC
Count
Min.
Typ.2 Max.
Unit
SOUTx Output Warning Period
SOUTx Output Warning Pulse Width
Horn Warning Pulse Period
Horn Warning Pulse Width
Horn Warning Pulse Spacing
Horn On-Time
Horn Off-Time
tsoutx
tw(soutx)
thorn
tw(horn)
tsp(horn)
ton(horn)
toff1(horn)
toff2(horn)
Low supply or degraded chamber
Low supply or degraded chamber
Low battery or degraded chamber
Low battery or degraded chamber
3 chirps, degraded chamber
Local, remote, or test alarm
Local, remote, or test alarm (see Timing
Diagrams section)
Local, remote, or test alarm (see Timing
Diagrams section)
212
38.9
43
47.1
s
1
9.5 10.5 11.5 ms
212
38.9
43
47.1
s
1
9.5 10.5 11.5 ms
26
0.60 0.67 0.74
s
48
450 500 550
ms
48
450 500 550
ms
144 1350 1500 1650 ms
Timer Mode Duration
ttimer
57344 9.0 10.0 11.0 min
Failed Push-Test Indication on SOUTx
tFAIL
After TEST input goes low
211 to
3072
211 ×
tosc
21.5 – 3072 ×
32.3
tosc
s
1Limits over the operating temperature range are based on characterization data. Characteristics are production tested at 25°C only.
2Typical values are at 25°C and are given for circuit design information only.
Allegro MicroSystems, Inc.
5
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com