English
Language : 

5350 Datasheet, PDF (5/8 Pages) Allegro MicroSystems – SMOKE DETECTOR WITH INTERCONNECT
5350
SMOKE DETECTOR
with INTERCONNECT
V12
OSC. CAP
INTERNAL
CLOCK
LED
SMOKE
COMPARATOR
HORN
TYPICAL APPLICATION
9V
TO
OTHER
UNITS
200 Ω
1 NC
2
NOTE
3
2
4 NC
330 Ω
5
LOGIC
OSC. &
TIMING
8.2 MΩ
6 V DD
7
HORN
DRIVER
1 µF
8
16
15
14
13
12
11
10
V SS 9
0.1 µF
PUSH
TO
TEST
NOTE 1
0.001 µF
Dwg. EC-005-3
NOTE 1: An external resistor divider is used to adjust sensitivity for the particular
smoke chamber.
NOTE 2: Abartetesrisytovor lttoaggerotuhnredsohrolVdD. D may be added to this pin to modify low
TIMING DIAGRAMS IN TYPICAL APPLICATION
NO ALARM
NO LOW BATTERY
STANDBY MODE
ALARM
NO LOW BATTERY
ALARM AND
LOW BATTERY
NO ALARM
LOW BATTERY
1.67 s
10 ms
40 ms
24 CLOCK CYCLES
LED OFF
SAMPLE
24 CLOCK CYCLES
LED
ON
12 CLOCK CYCLES
6 CLOCK CYCLES
6 CLOCK CYCLES
HORN
OFF
ON
30 CLOCK CYCLES
LOW BATTERY
WARNING
SMOKE
CHAMBER
V15 < V13 (NO SMOKE)
V15 > V13 (SMOKE)
Dwg. WC-003-1