English
Language : 

A1210_16 Datasheet, PDF (4/14 Pages) Allegro MicroSystems – Continuous-Time Latch Family
A1210, A1211,
A1212, A1213,
and A1214
Continuous-Time Latch Family
OPERATING CHARACTERISTICS over full operating voltage and ambient temperature ranges, unless otherwise noted
Characteristic
Symbol
Test Conditions
Min. Typ. Max. Units
Electrical Characteristics
Supply Voltage1
Output Leakage Current
Output On Voltage
Power-On Time2
Output Rise Time3
Output Fall Time3
Supply Current
Reverse Battery Current
VCC
Operating, TJ < 165°C
3.8
–
24
V
IOUTOFF
VOUT = 24 V, B < BRP
–
–
10
µA
VOUT(SAT)
IOUT = 20 mA, B > BOP
–
tPO
Slew rate (dVCC/dt) < 2.5 V/μs, B > BOP + 5 G or B < BRP
–5G
–
215
400
mV
–
4
µs
tr
VCC = 12 V, RLOAD = 820 Ω, CS = 12 pF
–
–
400
ns
tf
VCC = 12 V, RLOAD = 820 Ω, CS = 12 pF
–
–
400
ns
ICCON
ICCOFF
B > BOP
B < BRP
–
4.1
7.5
mA
–
3.8
7.5
mA
IRCC
VRCC = –30 V
–
–
–10
mA
Supply Zener Clamp Voltage
Supply Zener Current4
Magnetic Characteristics5
VZ
ICC = 10.5 mA; TA = 25°C
IZ
VZ = 32 V; TA = 25°C
32
–
–
V
–
–
10.5 mA
A1210
25
78
150
G
Operate Point
A1211
15
87
180
G
BOP
A1212
South pole adjacent to branded face of
device
50
107
175
G
A1213
80
–
200
G
A1214
140
–
300
G
A1210
–150 –78
–25
G
Release Point
A1211
–180 –95
–15
G
BRP
A1212
North pole adjacent to branded face of
device
–175 –117 –50
G
A1213
–200
–
–80
G
A1214
–300
–
–140
G
A1210
50
155
–
G
A1211
80
180
–
G
Hysteresis
BHYS
A1212
A1213
BOP – BRP
100
225
350
G
160
–
400
G
A1214
280
–
600
G
1 Maximum voltage must be adjusted for power dissipation and junction temperature, see Power Derating section.
2 For VCC slew rates greater than 250 V/μs, and TA = 150°C, the Power-On Time can reach its maximum value.
3 CS =oscilloscope probe capacitance.
4 Maximum current limit is equal to the maximum ICC(max) + 3 mA.
5 Magnetic flux density, B, is indicated as a negative value for north-polarity magnetic fields, and as a positive value for south-polarity magnetic fields. This so-called alge-
braic convention supports arithmetic comparison of north and south polarity values, where the relative strength of the field is indicated by the absolute value of B, and the
sign indicates the polarity of the field (for example, a –100 G field and a 100 G field have equivalent strength, but opposite polarity).
DEVICE QUALIFICATION PROGRAM
Contact Allegro for information.
EMC (Electromagnetic Compatibility) REQUIREMENTS
Contact Allegro for information.
Allegro MicroSystems, LLC
4
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com