English
Language : 

A1162 Datasheet, PDF (3/23 Pages) Allegro MicroSystems – Programmable Precision Hall-Effect Switch with Advanced Diagnostics
A1162
Programmable Precision Hall-Effect
Switch with Advanced Diagnostics
OPERATING CHARACTERISTICS: Valid over full operating voltage and ambient temperature ranges, unless otherwise
specified
Characteristics
Electrical Characteristics
Symbol
Test Conditions
Min.
Typ.1
Max.
Unit
Supply Voltage
Output Leakage Current
Output Saturation Voltage
Output Current Limit
Power-On Time 2
Chopping Frequency
Output Rise Time 2,3
Output Fall Time 2,3
Supply Current
Reverse-Battery Current
Supply Zener Clamp Voltage
Output Zener Voltage
Diagnostic Characteristics
PWM Carrier Frequency
Duty Cycle (Diagnostic Mode) 4
DIAG Pin Input Resistance
DIAG Pin Input Low Voltage
Threshold
VCC
IOUTOFF
VOUT(SAT)
IOM
tON
fC
tr
tf
ICC(ON)
ICC(OFF)
ICC(DIAG)
IRCC
VZSUP
VZOUT
Operating, TJ < 165°C
VOUT = 24 V, B < BRP
IOUT = 20 mA, B > BOP
B > BOP
VCC > 3.8 V, B < BRPmin – 10 G,
B > BOPmax + 10 G
RLOAD = 820 Ω, CL = 20 pF
RLOAD = 820 Ω, CL = 20 pF
B > BOP
B < BRP
DIAG = 1, TJ < TJ(MAX)
VRCC = –18 V
ICC = 8 mA, TA = 25°C
IOUT = 3 mA, TA = 25°C
fPWMout
DCFAIL
DCFAIL
DCPASS
RDIAG
VIL
With diagnostic mode enabled
DIAG = 1, Device Malfunction
DIAG = 1, Device Malfunction
DIAG = 1, Device Normal
DIAG pin pulled low
Device in Normal Mode
3.8
–
24
V
–
–
10
µA
–
185
400
mV
30
–
60
mA
–
–
25
µs
–
400
–
kHz
–
0.2
2
µs
–
0.1
2
µs
–
–
5
mA
–
–
5
mA
–
16
25
mA
–
–
–10
mA
30
–
–
V
28
–
–
V
–
3
–
kHz
–
0
40
%
60
100
–
%
40
50
60
%
–
1
–
MΩ
–
–
0.6
V
DIAG Pin Input High Voltage
Threshold
VIH
Device in Diagnostic Mode
1.5
–
5
V
Diagnostic Time
The diagnostics feature should be enabled
tD
for at least tD in order to obtain an accurate
1
–
–
ms
PWM signal.
Diagnostic Disable Time
tDIS
Time from when DIAG pin is released (High
to Low transition) to valid device output
–
–
25
µs
Continued on next page...
1 Typical data is at TA = 25ºC and VCC = 12 V and it is for design information only.
2 Power-on time, Rise time and Fall time are guaranteed through device characterization and not final test.
3 CL = oscilloscope probe capacitance.
4 When the DUT passes the diagnostic tests, the output will be a 50% duty cycle signal. Any other output indicates the DUT failed the test. Please see the application notes for
more information.
Allegro MicroSystems, LLC
3
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com