English
Language : 

3422 Datasheet, PDF (3/10 Pages) Unisonic Technologies – HIGH PERFORMANCE DUAL BIPOLAR OPERATINAL AMPLIFIER
3422
HALL-EFFECT,
DIRECTION-DETECTION
SENSOR
ELECTRICAL CHARACTERISTICS over operating temperature range.
Characteristic
Symbol Test Conditions
Min.
Limits
Typ. Max.
Supply Voltage Range
Output Leakage Current
Output Saturation Voltage
Power-On State
Undervoltage Lockout
Undervoltage Hysteresis
Power-On Time
Output Rise Time
Output Fall Time
Direction Change Delay
Supply Current
VCC
IOFF
VOUT(SAT)
POS
VCC(UV)
VCC(hys)
tpo
tr
tf
td
ICC
Operating, TJ < 165°C1
VOUT = VCC = 18 V
IOUT = 20 mA
VCC = 0 → 5 V,
BRP1 < B < BOP1, BRP2 < B < BOP2
IOUT = 20 mA, VCC = 0 → 5 V
Lockout (VCC(UV)) - Shutdown
VCC > 4.5 V
CL = 20 pF, RL = 820 Ω
CL = 20 pF, RL = 820 Ω
CL = 20 pF, RL = 820 Ω
VCC = 8 V, All outputs OFF
4.5
—
—
OFF
—
<1.0
0.21
OFF
18
10
0.50
OFF
—
3.5
—
—
0.5
—
—
—
50
—
200
—
—
200
—
0.5
1.0
5.0
5.0
9.0
18
NOTES:1. Maximum supply voltage must be adjusted for power dissipation and ambient temperature.
2. Typical Data is at VCC = 12 V and TA = +25°C and is for design information only.
Units
V
µA
V
—
V
V
µs
ns
ns
µs
mA
0.6
0.5
0.4
0.3
RθJA = 164°C/W
0.2
0.1
0
25
50
75
100
125
150
175
TEMPERATURE IN °C
Dwg. GH-069
www.allegromicro.com
3