■ Operation Overview
Function, register map and testing tool can be controlled by this control soft. These controls are selected by upper tabs.
Buttons which are frequently used such as register initializing button “Write Default”, are located outside of the
switching tab window. Refer to the “■ Dialog Boxes” for details of each dialog box setting.
1. [Port Reset]: For when connecting to USB I/F board (AKDUSBIF-A)
Click this button after the control soft starts up when connecting USB I/F board
(AKDUSBIF-A).
2. [Write Default]: Register Initializing
When the device is reset by a hardware reset, use this button to initialize the registers.
3. [All Write]: Executing write commands for all registers displayed.
4. [Save]: Saving current register settings to a file.
5. [Load]: Executing data write from a saved file.
6. [Data R/W]: “Data R/W” dialog box is popped up.
Figure 6. Window of [ Data R/W ]